Bus Ports (EtherCAT Ports)
Set the EtherCAT ports (input ports and output ports) as follows.
ID
Property name
Setting value
20026
Function definition
Network / bus cable connection, general
20308
Bus system
EtherCAT
20447
Bus interface: Name
EtherCAT
20310
Logical network: Bus port is master
Not selected.
20448
Bus interface: Main bus port
(a): Selected.
(b): Not selected.
(a)
(b)
NX-ECC203
Three-port Junction Slaves
PLC Box
Set the PLC box as follows.
ID
Property name
Setting value
20416
PLC type designation
Model name of the three-port junction slave
Example: "GX-JC03"
20427
Rack ID
0
20167
CPU
Not selected.
20164
Bus coupler / head station
Selected.
Bus Ports (EtherCAT Ports)
Set the EtherCAT ports of three-port junction slave models as follows.
ID
Property name
Setting value
20026
Function definition
Network / bus cable connection, general
20308
Bus system
EtherCAT
20447
Bus interface: Name
EtherCAT
20310
Logical network: Bus port is master
Not selected.
3 Setting EPLAN Electric P8
3-4
Sysmac Studio Electrical CAD Connector Function Practices Guide for AutomationML Import (EPLAN Electric P8) (P156)