4-2
Section
Structure Descriptions
59
Type
Contents
Variable name
BYTE
byStatusFlag
Data link operation status and data link mode
Stores the data link operation status, data link mode, etc.
Bit
––: Not specified
Current Data Link Mode
0: User-set links
1: Automatic
Data Link Operating Status
0: Stopped
1: Running
BYTE
abyDataLinkStatus[62]
Data link status
Stores the data link status.
Bit
[0]
[1]
[2]
[60]
[61]
Node 1
Node 2
Node 3
Node 61
Node 62
Node Data Link Status
––: Not specified
PC Operating Status
0: Stopped
1: Running (PC program being executed.)
CPU Unit Error Status
0: No error
1: Error
Data Link Communications Error Status
0: Normal
1: Error (Data link data not received normally.)
Data Link Participation Status
0: Not participating or data links stopped
1: Participating
Offset Error Status (Offset larger than number of send words)
0: Normal
1: Error
Insufficient Reception Area
0: Normal
1: Insufficient
Excess Reception Area
0: Normal
1: Excess
Note
For Wired Systems, the above information is valid through node 32
(abyDataLinkStatus[32]).
(Data larger than data link reception area.
Overflow data discarded.)
(Data smaller than data link reception area.
Overflow area data not specified.)
Содержание SYSMAC 3G8F7-CLK12-E
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 16: ......
Страница 30: ...1 2 Section Specifications and Configurations 14 1 2 5 Dimensions Wired Model 3G8F7 CLK21 E Unit mm ...
Страница 36: ......
Страница 56: ......
Страница 62: ......
Страница 78: ......
Страница 94: ......
Страница 128: ......
Страница 140: ......
Страница 158: ......