![Omron SYSMAC 3G8F7-CLK12-E Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/omron/sysmac-3g8f7-clk12-e/sysmac-3g8f7-clk12-e_operation-manual_1633420033.webp)
1-3
Section
Basic Procedures
17
1-2-8 Software Configuration
Software
Hardware
User application
C Library
Controller Link Support Board
FinsGateWay
FinsGateway
utilities
Note A CLK data link setting utility is included in the FinsGateway utilities. Make the
data link table settings for the Board using this utility. For details, refer to Fins-
Gateway online help.
1-2-9 Applicable Computers, Operating Systems, and Libraries
Controller Link
Support Board
Applicable computer
Applicable
operating system
Applicable
language
All models
IBM PC/AT or compatible
CPU: Intel Celeron 400 MHz or later
Main memory: 32 MB min.
One PCI bus slot must be available.
Available hard disk space: 70 Mbytes min. (not
including space for user applications)
CD-ROM drive: Required for software installation
Display: VGA (640 x 480 pixels) or better display
functionality
(Other conditions conform to those of the OS.)
Windows 98
Windows 2000
Windows NT4.0
(Service Pack 3 or
later)
Microsoft Visual C++
Ver 6.0
(Service Pack 3)
Note
1. Operation of the Controller Link BIOS, Driver, and Library can be guaran-
teed only under the computer and operating system specified above.
Please use the specified computer and operating system.
2. Windows 95, Windows NT3.51 or earlier OS cannot support the Controller
Link Support Board.
1-3
Basic Procedures
Initial Procedure
Refer to the Controller Link Support Board Installation Guide for information on
the first three steps in the following procedure.
1, 2, 3...
1. Set the Board ID on the Board switch.
2. Install the Board into the computer.
3. Install the software.
4. Wire and connect the cables.
5. Perform the following data link and/or message service procedure.
Data Link Procedure
1, 2, 3...
1. Create data link tables using the Controller Link Support Software or the
FinsGateway utilities, and transfer the data to the Board.
Note When the data link tables and routing tables are transferred to the
Controller Link Support Board, they are saved in backup memory
(EEPROM) on the Board. It is not necessary to set the data again
when the power is turned OFF and ON.
Содержание SYSMAC 3G8F7-CLK12-E
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 16: ......
Страница 30: ...1 2 Section Specifications and Configurations 14 1 2 5 Dimensions Wired Model 3G8F7 CLK21 E Unit mm ...
Страница 36: ......
Страница 56: ......
Страница 62: ......
Страница 78: ......
Страница 94: ......
Страница 128: ......
Страница 140: ......
Страница 158: ......