4-2 Wiring
4-2-5 Conforming to EMC Directives
Case
Control panel
Door (interior view)
Oil-resistant gasket
Conductive gasket
Oil-resistant gasket
Conductive gasket
Cross-sectional view of A–B
Door
Selecting Connection Components
This section explains the criteria for selecting the connection components required to
improve noise resistance. Review each component’s characteristics, such as its capacity,
performance, and applicable conditions when selecting the components. For more details,
contact the manufacturers directly.
Fuses
Always install a fuse at each Servo Driver to prevent fire or burn damage. We
recommend the following fuses, based on the rated current, current at the maximum
momentary torque, and inrush current when the power is turned ON.
Servo Driver
Fuse (Littelfuse, Inc.)
Fuse block (Littelfuse, Inc.)
Model
Capacity
(W)
Momentary
rating
A (rms)
Model
Rating
A
Inrush
A
0-P
Model Specifications
R7D-ZP01H
100
4
R7D-ZP02H
200
4
R7D-ZP04H
400
8
KLK015
15
30
R7D-ZP08H
750
16
KLK030
30
60
L60030M
-2SQ
Max. AC voltage: 600 V
Max. rated current: 30 A
Screw/Q.C. Terminals
4-14
Содержание SMARTSTEP Junior R7D-ZP
Страница 3: ...2 ...
Страница 18: ...Section 1 Configuration Features and System ...
Страница 25: ...1 5 Applicable Standards 1 5 2 UL and cUL Standards 1 8 ...
Страница 26: ...Section 2 Dimensions Standard Models and ...
Страница 36: ...Section 3 Specifications ...
Страница 62: ...Section 4 System Design ...
Страница 86: ...Section 5 Operation ...
Страница 96: ...Section 6 Troubleshooting ...
Страница 109: ...6 5 Periodic Maintenance 6 5 3 Replacing the Cooling Fan 6 14 ...
Страница 110: ...Appendix ...