![Omron SMARTSTEP Junior R7D-ZP Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/omron/smartstep-junior-r7d-zp/smartstep-junior-r7d-zp_user-manual_741365038.webp)
3-1 Servo Driver Specifications
3-1-2 Characteristics
3-1-2 Characteristics
Control Specifications
R7D-
Item
ZP01H
ZP02H
ZP04H
ZP08H
Continuous output current (rms)
0.84 A
1.1 A
2.0 A
3.7 A
Momentary maximum output current
(rms)
2.5 A
3.3 A
6.0 A
11.1 A
Input power supply
(For main circuit and control circuit)
Single-phase 200 to 230 VAC (170 to 253 V), 50/60 Hz
Main circuit
6 W
8 W
16 W
27 W
Heat generated
Control circuit
8 W
8 W
8 W
8 W
Control method
All-digital servo
Inverter method
IGBT-driven PWM method
Maximum response frequency
(command pulses)
750 kpps
Weight
0.5 kg
1.0 kg
Applicable motor capacity
100 W
200 W
400 W
750 W
Applicable Servomotors (R7M-)
Z10030-S1
Z20030-S1
Z40030-S1
Z75030-S1
3-1-3
Main Circuit and Servomotor Connector Specifications (CNA
and CNB)
R7A-CNZ01P (CNA) Main Circuit Connector Specifications
CNA Connector
Main Circuit Connector (CNA) Pin Arrangement
Signal No.
Signal
Function
Condition
1 L1
2 L2
Main circuits power supply
input
Single-phase 200/230 V AC
(170 to 253 V AC) 50/60 Hz
3 +
4
−
Regeneration Resistance
Unit connection terminals
If regenerative energy is high, connect a
Regeneration Resistance Unit between P and
N.
Frame ground
This is the ground terminal. Ground to a
minimum of 100
Ω
(class D, class 3).
3-3
Содержание SMARTSTEP Junior R7D-ZP
Страница 3: ...2 ...
Страница 18: ...Section 1 Configuration Features and System ...
Страница 25: ...1 5 Applicable Standards 1 5 2 UL and cUL Standards 1 8 ...
Страница 26: ...Section 2 Dimensions Standard Models and ...
Страница 36: ...Section 3 Specifications ...
Страница 62: ...Section 4 System Design ...
Страница 86: ...Section 5 Operation ...
Страница 96: ...Section 6 Troubleshooting ...
Страница 109: ...6 5 Periodic Maintenance 6 5 3 Replacing the Cooling Fan 6 14 ...
Страница 110: ...Appendix ...