102
Read Controller Information
Section 6-4
6-4
Read Controller Information
This service reads the Controller's model and version.
■
Service Request PDU
■
Service Response PDU
(1) Model
The S8AS's model number is returned in 20 bytes of ASCII data. If the data
is less than 20 bytes long, the remaining bytes will be padded with spaces
(20 hex).
The following table shows the model number format.
(2) Version
The version number is returned in 20 bytes of ASCII data. If the data is less
than 20 bytes long, the remaining bytes will be padded with spaces (20
hex).
Example: “V1.00”
The remaining 15 bytes are all spaces.
MRC SRC
0 5 0 1
2 2
MRC
SRC
0
5
0
1
2
2
4
20
20
Response Code
Model
Version
Model
Code (4 bytes)
Same in all models
S8AS
−
Code (1 byte)
−
−
Capacity
Code (3 bytes)
240 W
240
480 W
480
Number of branch outputs
Code (2 bytes)
1
01
2
02
:
:
8
08
Communications specification
Code (1 byte)
No communications, settings can
be changed
All spaces
No communications, settings can-
not be changed
N
Communications, settings can be
changed
R
Remaining bytes
(9 bytes)
−
All spaces
Содержание S8AS
Страница 1: ...S8AS Smart Power Supply USER S MANUAL Cat No Z269 E1 05...
Страница 2: ......
Страница 3: ...S8AS Smart Power Supply User s Manual Revised September 2013...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 104: ...86 Run Mode Section 5 4...
Страница 128: ...110 ASCII List Section 6 10 6 10 ASCII List Even parity...
Страница 144: ...126 Revision History...
Страница 145: ......