85
Run Mode
Section 5-4
Note
(1) The S8AS, however, has a current-restricting function, so the peak value
is not necessarily an accurate measure of the peak inrush current of the
connected device.
(2) Due to the startup delay the peak output current display value may be
greater than the abnormal current tripping threshold.
Press the
Key. Clearing the peak time will be started and
“0.0” will flash on the display.
When “0.0” stops flashing, the clear process has been com-
pleted and the present current will be displayed as the peak
output current.