4 Safety Function Blocks
4 - 62
NX-series Safety Control Unit Instructions Reference Manual (Z931)
Note “X” in “S_ModeX” and “S_ModeXSel” indicates a number between 0 and 7.
S_Mode4
SAFEBOOL TRUE or FALSE
FALSE
A constant or a variable. It is input 4 from the mode selection
switch.
FALSE: No request was made by the operator to select mode
4.
TRUE: A request was made by the operator to select mode 4.
S_Mode5
SAFEBOOL TRUE or FALSE
FALSE
A constant or a variable. It is input 5 from the mode selection
switch.
FALSE: No request was made by the operator to select mode
5.
TRUE: A request was made by the operator to select mode 5.
S_Mode6
SAFEBOOL TRUE or FALSE
FALSE
A constant or a variable. It is input 6 from the mode selection
switch.
FALSE: No request was made by the operator to select mode
6.
TRUE: A request was made by the operator to select mode 6.
S_Mode7
SAFEBOOL TRUE or FALSE
FALSE
A constant or a variable. It is input 7 from the mode selection
switch.
FALSE: No request was made by the operator to select mode
7.
TRUE: A request was made by the operator to select mode 7.
S_Unlock
SAFEBOOL TRUE or FALSE
FALSE
A constant or a variable. It locks or unlocks the selected mode.
FALSE: The actual
S_ModeXSel
output is locked, so the
S_ModeXSel
output will not change even if the
S_ModeX
input
has changed when
S_SetMode
changes to TRUE.
TRUE: The mode can be changed because the selected
S_ModeXSel
output is not locked.
S_SetMode SAFEBOOL TRUE or FALSE
FALSE
A constant or a variable. If
AutoSetMode
is FALSE, this variable
executes the selected mode change.
TRUE: The selected mode is set when this variable changes to
TRUE.
FALSE: If
AutoSetMode
is TRUE, a constant FALSE is set.
When the operator changes the mode selection switch,
S_AnyModeSel
and
S_ModeXSel
change to FALSE. The mode
change is executed when
S_ModeXSel
changes to TRUE as
the result of
S_SetMode
changing to TRUE.
AutoSet-
Mode
BOOL
TRUE or FALSE
FALSE
A constant. It sets mode confirmation.
FALSE: To change the mode, the operator must confirm the
change with the
S_SetMode
input.
TRUE: Even if the operator does not confirm the change with
the
S_SetMode
, the
S_ModeXSel
output will change automati-
cally when the
S_ModeX
input changes. (However, the opera-
tion is the same as for FALSE if the mode is locked with
S_Unlock
.)
ModeMoni-
torTime
TIME
Depends on data
type.
T#0ms
A constant. It is the maximum allowable time to change the
selection input.
Reset
BOOL
TRUE or FALSE
FALSE
Refer to
Safety FB Common Input Variables
Variable
Data type
Valid range
Default
Description
Содержание NX-SL series
Страница 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 14: ...Terms and Conditions Agreement 12 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 130: ...3 Safety Standard Function Blocks 3 20 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Страница 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Страница 269: ......