4 - 87
4 Safety Function Blocks
NX-series Safety Control Unit Instructions Reference Manual (Z931)
4
SF
_Muting
P
a
r_2Sensor
S_StartReset = TRUE, Reset = FALSE, and S_MutingLamp = TRUE
Error Detected
The FB detects the following errors.
•
DiscTimeEntry
is set to less than T#0s or more than T#4s.
•
MaxMutingTime
is set to less than T#0s or more than T#10min.
• The discrepancy time for the sensor pair (
S_MutingSwitch11
and
S_MutingSwitch12
) exceeded
the set value.
• Muting (
S_MutingActive
= TRUE) exceeded
MaxMutingTime
(maximum muting time).
• The muting sensors (S_
MutingSwitch11
and
S_MutingSwitch12
) operated in an incorrect order.
• A muting sequence started without being enabled by
MutingEnable
.
• A muting sensor signal that is always TRUE was detected.
• A muting lamp failure was indicated (
S_MutingLamp
= FALSE).
• An undetected change to TRUE in the
Reset
input was detected in the Init state or the Wait for
Reset state.
Operation for Errors
• When an error occurs, the
S_AOPD_Out
and
S_MutingActive
outputs are set to FALSE. The
DiagCode
output gives the relevant error code and the
Error
output is set to TRUE.
• Operation is not restarted until the error is reset and the operator acknowledges the safe state
with
Reset
.
FB-specific Error Codes
Timing Charts
Instruction Execution Errors
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
C001
49153
Reset Error 1
When the Init state was entered, an undetected
change to TRUE in the
Reset
input was detected.
Ready
= TRUE
S_AOPD_Out
= FALSE
S_MutingActive
= FALSE
Error
= TRUE
Activate
S_AOPD_In
MutingEnable
S_MutingSwitch11
S_MutingSwitch12
S_AOPD_Out
S_MutingActive
Error
DiagCode
8000 / 8011
0000 / 8000
8012
8012
8000
8000
8000
8000
8000
8000
8000
8000
Содержание NX-SL series
Страница 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 14: ...Terms and Conditions Agreement 12 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 130: ...3 Safety Standard Function Blocks 3 20 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Страница 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Страница 269: ......