4 - 47
4 Safety Function Blocks
NX-series Safety Control Unit Instructions Reference Manual (Z931)
4
SF_ES
PE
Error Detected
This FB detects an undetected change to TRUE in the
Reset
input as an error.
Operation for Errors
•
S_ESPE_Out
is set to FALSE. If there is an undetected change to TRUE in the
Reset
input, the
DiagCode
output gives the relevant error code and the
Error
output is set to TRUE.
• To reset the error, you must set
Reset
to FALSE.
FB-specific Error Codes
FB-specific State Codes (No Error)
Instruction Execution Errors
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
C001
49153
Reset Error 1
When the Wait for Reset 1 state was entered, an
undetected change to TRUE in the
Reset
input
was detected.
Ready
= TRUE
S_ESPE_Out
= FALSE
Error
= TRUE
C002
49154
Reset Error 2
When the Wait for Reset 2 state was entered, an
undetected change to TRUE in the
Reset
input
was detected.
Ready
= TRUE
S_ESPE_Out
= FALSE
Error
= TRUE
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
0000
0
Idle
The FB is disabled (default).
Ready
= FALSE
S_ESPE_Out
= FALSE
Error
= FALSE
8001
32769
Init
The FB is active. The FB is already started. See if
S_StartReset
is required.
Ready
= TRUE
S_ESPE_Out
= FALSE
Error
= FALSE
8002
32770
Wait for S_ESPE_In 1
The FB is active. Make sure that
Reset
is FALSE.
The FB is waiting for
S_ESPE_In
to change to
TRUE.
Ready
= TRUE
S_ESPE_Out
= FALSE
Error
= FALSE
8003
32771
Wait for Reset 1
The FB is active.
S_ESPE_In
is
TRUE.
The FB is
waiting for
Reset
to change to TRUE.
Ready
= TRUE
S_ESPE_Out
= FALSE
Error
= FALSE
Содержание NX-SL series
Страница 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 14: ...Terms and Conditions Agreement 12 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 130: ...3 Safety Standard Function Blocks 3 20 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Страница 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Страница 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Страница 269: ......