17
Connecting to DeviceNet
Section 2-3
2-3-3
DeviceNet Node Address and Baud Rate Software Settings
Use the following procedure to set the ED Router DeviceNet node address
and baud rate from the Network Configurator.
1,2,3...
1.
Select
Programs - OMRON Network Configurator for DeviceNet Safety
- Network Configurator
from the Start Menu. The Network Configurator
will be started.
2.
Connect the Network Configurator online. (First set the interface with
Op-
tion - Select Interface
, and then select
Network - Connect
.)
3.
Select DeviceNet in the Network Configuration Window. (For example,
click the
DeviceNet_1
Tab.)
4.
Select
Tool - Node Address/Baud Rate Setting
.
The following dialog box will be displayed.
5.
Specify the present node address of the target ED Router in the
Target
Node Address
Field.
6.
To change the node address, specify a new node address in the
New Node
Address
Field and click the
Change
Button.
The node address of the ED Router will be changed.
7.
To change the baud rate, select the rate in the
New Baud Rate
Field and
click the
Change
Button.
The baud rate of the ED Router will be changed.
Содержание NE1A-EDR01
Страница 1: ...OPERATION MANUAL Cat No Z912 E1 01 NE1A Series NE1A EDR01 EtherNet IP DeviceNet Router...
Страница 2: ...NE1A Series EtherNet IP DeviceNet Router NE1A EDR01 Operation Manual Produced July 2007...
Страница 3: ...iv...
Страница 7: ...viii TABLE OF CONTENTS...
Страница 9: ...x...
Страница 13: ...xiv...
Страница 41: ...24 ED Router Settings Section 2 5...
Страница 53: ...36 Error History Section 3 3...
Страница 97: ...80 DST1 Series Monitoring Section 4 7...
Страница 101: ...84 Settings from the Network Configurator Appendix B...
Страница 105: ...88 Glossary...
Страница 107: ...90 Revision History...