Regular Payload Series-Hardware Installation Manual TM5 Series
42
5.3.3 Digital In/Out
Digital input/output each has 16 channels, and its application is connected to the following sections.
5.3.3.1 Digital Input
Inputs can be set to either sink input or source input by selection.
Set to sink input type
When a device such as a transistor output sensor is connected, NPN open collector transistor output
can be used.