Regular Payload Series-Hardware Installation Manual TM5 Series
53
5.6 Control Box Power Interface and Robot Interface
5.6.1 Control Box Power Interface
TM5-700 / TM5-900:
The power cable of the control box has an IEC plug. The local power plug is connected to the IEC plug.
TM5M-700/ TM5M-900:
The power cable of the control box has Hirose (HRS) DF60 series connector.
The power supply should be equipped with the following:
•
Grounding
•
Main fuse
•
Residual current device (RCD)
It is recommended to install a master switch on the equipment power supply for robot applications for
servicing and inspection.
AC Adapter
AC Adapter
:
IEC plug
DC IN Power Connector
:(
HRS
)
DF60-3EP-10.16C
DC IN for External Power Supply Connector
:
Contact OMRON for purchasing
External Power Supply Remote Control Connector
:
Contact OMRON for
purchasing
DC IN Power
External Power Supply Remote Control
DC IN for External Power Supply
-
+
TM5M-700/ TM5M-900
TM5-700 / TM5-900