![Omron Medium & Heavy Payload Series Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/omron/medium-and-heavy-payload-series/medium-and-heavy-payload-series_hardware-installation-manual_743976038.webp)
Regular Payload Series-Hardware Installation Manual TM5 Series
38
5.3.1 Safety Connector
Provides extension ports for Emergency Stop (ESTOP) & Safeguard Port.
1. ESTOP is a N.C. contact (Normally closed). When any connected ESTOP switch is OPEN, the robot
enters the Emergency STOP state.
2. Safeguard A Port is a N.C. contact (Normally closed). When Safety A switch is OPEN, the robot enters
the Safeguard Pause state.
3. Safeguard B Port is a N.C. contact (Normally closed). When Safety B switch is OPEN, the robot enters
the Safeguard Collaborative Mode state.