39
3.
Basic use
3.2 Switching between modes
Switching between the measuring mode and the setting mode
Switch between the measuring mode and setting mode by pressing and holding the [<</MODE] key.
• "Press and hold" means pressing the key for 1 or more seconds.
■
Measuring mode
→
Setting
mode
Screen to enter the password
→
Enter password
(password authentication OK)
→
"SET MODE" displayed
→
Setting mode
The initial password is "0001."
■
Setting mode
→
Measuring mode
1
If settings are not changed in the setting mode
"MEASR MODE" displayed
→
Measuring mode
2
If settings are changed in the setting mode
"SAVE" display
→
restart
→
Measuring mode
– Restarting is done automatically.
Switching between the measuring mode and the communication setting mode
You can switch between the communication setting mode and the measuring mode by sending particular commands.
Refer to "6.Detailed settings for communications (
69)" for details about the commands to move to each mode.
■
Switching from measuring mode to
communication setting mode
Command sent
→
"COMM MODE" displayed
("COMM MODE" is displayed while in communication
setting mode)
■
Switching from communication setting
mode to measuring mode
Command sent
→
"MEASR MODE" displayed
→
Measuring mode
1
If settings are not changed in the communication setting
mode
"MEASR MODE" displayed
→
Measuring mode
2
If settings are changed in the communication setting mode
"SAVE" displayed
→
restart
→
Measuring mode
– Restarting is done automatically.
Measuring
mode
Setting mode
Screens
<</MODE
Press and hold
Password
Authenticated
Automatic transition
Setting
mode
Setting mode
Screens
<</MODE
Press and hold
Automatic transition
Setting
mode
Setting mode
Screens
<</MODE
Press and hold
Restart
Measuring mode
Screens
Command
Measuring
mode
Command
Automatic transition
Command
Restart