2.6 Pulse output wiring (continued)
2 Removing Wires from Push-In Plus Terminal Block
Use the following procedure to remove wires from the terminal
block. The same method is used to remove stranded wires,
solid wires, and ferrules.
1 Hold a flat-blade screwdriver at an angle and insert it into
the release hole.
2 With the screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
3 Remove the flat-blade screwdriver from the release hole.
3 Recommended Tools
• ecommended Flat-blade Screwdriver
Use a flat-blade screwdriver to connect and remove wires.
Use the following flat-blade screwdriver.
* SZF 0-0.4 x 2.5 (Phoenix Contact) is can be arranged
from Omron XW4Z-00B.
Model
Manufacturer
ESD0.40 x 2.5
Wera
SZF 0.4 x 2.5
SZF 0-0.4 x 2.5 *
Phoenix Contact
0.4 x 2.5 x 75 302
Wiha
AEF.2.5 x 75
Facom
210-719
Wago
SDI 0.4 x 2.5 x 75
Weidmuller