6-4
I/O Allocation
Section 4-2
Rem
o
te
I
/O
Com
-
m
u
ni
c
a
ti
o
ns
2.
K3HB-DRT Operation Data and Setting Data
Monitor values and setting data with communications addresses that be-
long to the following variable types can be allocated. Duplicate settings are
possible and are processed in ascending order.
Note
If items are allocated in the read-only area of the OUT Area, words
are allocated in memory but operate as if they had not been allo-
cated.
3.
Output Enable Bits
Output Enable Bits are allocated in the first word of the OUT Area.
When Output Enable Bits are allocated in the IN Area, they are always set
to 0 (OFF).
Note
If data allocated to the IN or OUT Area is changed, use a software reset or
cycle the power to enable the new settings.
4-2-3
Allocation Default Values
The default values for I/O allocations are listed in the following table.
4-2-4
Allocation Settings
The I/O allocation settings are listed in the following table.
Variable type
C0
Operation monitor data
C2
RUN level
Area
Item
IN Area
Measurement value
OUT Area
Output Enable Bits
Operation commands
Allocated
to IN
Area
Allocated
to OUT
Area
Configurator display
Setting data name
Allocation data size
No
Yes
−
1
OUT Enabled Bits
2 bytes, fixed
No
Yes
Operation command
Operation command
Default value: 2 bytes
No
No
Generic status
Generic status
Default value: 2 bytes
Yes
No
Status
Status
4 bytes, fixed
Yes
No
Measurement value
Measurement value
Default value: 2 bytes
Yes
No
Maximum value
MAX value
Default value: 2 bytes
Yes
No
Minimum value
MIN value
Default value: 2 bytes
Yes
Yes
Comparative set value HH (OUT5)
Comparative set value HH (OUT5)
Default value: 2 bytes
Yes
Yes
Comparative set value H (OUT4)
Comparative set value H (OUT4)
Default value: 2 bytes
Yes
Yes
Comparative set value L (OUT2)
Comparative set value L (OUT2)
Default value: 2 bytes
Yes
Yes
Comparative set value LL (OUT1)
Comparative set value LL (OUT1)
Default value: 2 bytes
Yes
Yes
Comparative set value PASS (OUT3) Comparative set value PASS (OUT3) Default value: 2 bytes
Содержание K3HB
Страница 2: ...K3HB Digital Indicators Communications User s Manual Revised March 2005...
Страница 3: ...iv...
Страница 15: ...xvi...
Страница 19: ...xx...
Страница 21: ...Part 1 CompoWay F...
Страница 69: ...Part 2 DeviceNet...
Страница 95: ...6 10 Ladder Programming Examples Section 4 3 Remote I O Com munications...
Страница 103: ...7 8 Explicit Messages Specific to DeviceNet compatible Digital Indicators Section 5 3 Explicit Message Communications...
Страница 111: ...8 8 Message Communications Performance Section 6 2 Communications Performance...
Страница 127: ...Part 3 BCD Output...
Страница 147: ......