2-11
List of Settings
Section 2
Lis
t of
Se
tting
s
K3HB-R/P
Communications Monitoring Settings
Note
The values beginning with H' in the
Monitor/Setting range
column are used when setting or monitor-
ing data via communications.
Protect Level
Note
The values beginning with H' in the
Monitor/Setting range
column are used when setting or monitor-
ing data via communications.
RUN Level
Note
The values beginning with H' in the
Monitor/Setting range
column are used when setting or monitor-
ing data via communications.
Variable
type
Address
Parameter
name
Charac-
ter
Monitor/Setting range
Character
Default
setting
Decimal point
Unit
C0
0000
Version
---
---
---
---
---
---
0001
Status
---
---
---
---
---
---
0002
Measurement
value
---
H’FFFFB1E1 to H’0001869F:
−
19999 to 99999
(Time limit is OFF. Lower limit of P is 0.)
H’00000000 to H’0001869F: 0 to 99999 (Time unit is
min.)
H’00000000 to H’000176D7: 0.00.00 to 9.59.59
(Time unit is hr:min:s.)
H’00000000 to H’0001850F: 00.00.0 to 99.59.9
(Time unit is min:s:ms.)
---
---
---
---
0003
Max. value
---
Same as above
---
---
---
---
0004
Min. value
---
Same as above
---
---
---
---
Variable
type
Address
Parameter
name
Charac-
ter
Monitor/Setting range
Character
Default
setting
Decimal point
Unit
C1
0000
RUN/adjustment
protect
run.pt
H’00000000 to H’00000002: (0 to 2)
0
to
2
0
---
---
0001
Setting level
protect
set.pt
H’00000000 to H’00000002: (0 to 2)
0
to
2
1
---
---
0002
Setting change
protect
wt.pt
H’00000000: OFF (0)
H’00000001: ON (1)
off
,
on
off
---
---
0003
Max/Min protect
mmpt
H’00000000 to H’00000002: (0 to 2)
0
to
2
0
---
---
Variable
type
Address
Parameter
name
Charac-
ter
Monitor/Setting range
Character
Default
setting
Decimal point
Unit
C2
0000
Measurement
value/comparative
set value HH
---
H’FFFFB1E1 to H’0001869F:
−
19999 to 99999
(Time limit is OFF. Lower limit of P is 0.)
H’00000000 to H’0001869F: 0 to 99999 (Time unit is
min.)
H’00000000 to H’000176D7: 0.00.00 to 9.59.59
(Time unit is hr:min:s.)
H’00000000 to H’0001850F: 00.00.0 to 99.59.9
(Time unit is min:s:ms.)
:9999
to
99999
0.
00.
00
to
99999
0.
00.
00
to
9.
59.
59
0.
00.
00
to
99.
59.
9
99999
According to the
decimal position
setting. The time
unit, however, is
indicated as
*.**.** for
hr:min:s and
as **.**.* for
min:s:ms.
---
0001
Measurement
value/compara-
tive set value H
---
Same as above
Same as above
99999
Same as above
---
0002
Measurement
value/compara-
tive set value L
---
Same as above
Same as above
R:
:9999
P:
0
Same as above
---
0003
Measurement
value/compara-
tive set value LL
---
Same as above
Same as above
R:
:9999
P:
0
Same as above
---
Содержание K3HB
Страница 2: ...K3HB Digital Indicators Communications User s Manual Revised March 2005...
Страница 3: ...iv...
Страница 15: ...xvi...
Страница 19: ...xx...
Страница 21: ...Part 1 CompoWay F...
Страница 69: ...Part 2 DeviceNet...
Страница 95: ...6 10 Ladder Programming Examples Section 4 3 Remote I O Com munications...
Страница 103: ...7 8 Explicit Messages Specific to DeviceNet compatible Digital Indicators Section 5 3 Explicit Message Communications...
Страница 111: ...8 8 Message Communications Performance Section 6 2 Communications Performance...
Страница 127: ...Part 3 BCD Output...
Страница 147: ......