2-10
List of Settings
Section 2
Lis
t of
Se
ttings
Communications Setting Level
Note
The values beginning with H’ in the
Monitor/Setting range
column are used when setting or monitoring
data via communications.
Advanced Function Setting Level
Note
(1) The values beginning with H’ in the
Monitor/Setting range
column are used when setting or monitoring
data via communications.
(2) If the event connector is provided as a standard feature or an event connector is added, use EV for
the “bank selection” setting.
Variable
type
Address
Parameter
name
Character
Monitor/Setting range
Character
Default
setting
Decimal
point
Unit
Model
X
V
S
H
CA
0000
Unit No.
u-no
H’00000000 to
H’00000063: (0 to 99)
0
to
99
1
---
---
0001
Baud rate
bps
H’00000000: 9.6(0),
H’00000001: 19.2(1),
H’00000002: 38.4(2)
9
.
6
,
19
.
2
,
38
.
4
9
.
6
---
kbps
0002
Data length
len
H’00000000: 7(0),
H’00000001: 8(1)
7
,
8
7
---
bit
0003
Stop bit
length
sbit
H’00000000: 1(0),
H’00000001: 2(1)
1
,
2
2
---
bit
0004
Parity
prty
H’00000000: None (0),
H’00000001: Even (1),
H’00000002: Odd (2)
none
,
even
,
odd
even
---
---
0005
Send wait
time
sdwt
H’00000000 to
H’00000063 (0 to 99)
0
to
99
20
---
ms
Variable
type
Address
Parameter
name
Charac-
ter
Monitor/Setting range
Character
Default
setting
Decimal
point
Unit
Model
X
V
S
H
CB
0000
PASS-output
change
pass
H’00000000: LL(0), H’00000001:
L(1), H’00000002: PASS(2),
H’00000003: H(3), H’00000004:
HH(4), H’00000005: ERR(5)
ll
,
l
,
pass
,
h
,
hh
,
err
pass
---
---
0001
Hysteresis
hys
H’00000000 to
H’0000270F: (0 to 9,999)
0
to
9999
1
According to
the decimal
position set-
ting
---
0002
Output OFF
delay
off-d
H’00000000 to
H’000007CF (0 to 1,999)
0
to
1999
0
---
S: ms
Others:
100 ms
0003
Shot output
shot
H’00000000 to
H’000007CF (0 to 1,999)
0
to
1999
0
---
S: ms
Others:
100 ms
0004
Output logic
out-n
H’00000000: Close in alarm(0),
H’00000001: Open in alarm(1)
n-o
,
n-c
n-o
---
---
0005
Output
refresh stop
o-stp
H’00000000: OFF(0), H’00000001:
OUT(1), H’00000002: ALL(2)
off
,
out
,
all off
---
---
0006
Tare zero
t-zr
H’00000000: OFF(0)
H’00000001: ON(1)
off
,
on
off
---
---
x
0007
Zero trim-
ming
z-trm
H’00000000: OFF(0)
H’00000001: ON(1)
off
,
on
off
---
---
x
0008
Previous
average
value com-
parison
hp-f
H’00000000: OFF(0)
H’00000001: ON(1)
off
,
on
off
---
---
0009
Bank selec-
tion
bnk-c
H’00000000: OFF(0), H’00000001:
KEY(1), H’00000002: EV(2)
off
,
key
,
ev
off
(See note.)
---
---
000A
Startup com-
pensation
timer
s-tmr
H’00000000 to
H’0000270F: (0 to 99.9)
0
.
0
to
99
.
9
0
.
0
1
s
000B
Input error
enable
s.err
H’00000000: Disable(0),
H’00000001: overflow(1),
H’00000002: input error(2)
off
,
over
,
s.err
s.err
---
---
000C
Standby
sequence
stdby
H’00000000: OFF(0)
H’00000001: ON(1)
off
,
on
off
---
---
000D
Cold junction
compensat-
ing circuit
cjc
H’00000000: OFF(0)
H’00000001: ON(1)
off
,
on
on
---
---
x
x
x
Содержание K3HB
Страница 2: ...K3HB Digital Indicators Communications User s Manual Revised March 2005...
Страница 3: ...iv...
Страница 15: ...xvi...
Страница 19: ...xx...
Страница 21: ...Part 1 CompoWay F...
Страница 69: ...Part 2 DeviceNet...
Страница 95: ...6 10 Ladder Programming Examples Section 4 3 Remote I O Com munications...
Страница 103: ...7 8 Explicit Messages Specific to DeviceNet compatible Digital Indicators Section 5 3 Explicit Message Communications...
Страница 111: ...8 8 Message Communications Performance Section 6 2 Communications Performance...
Страница 127: ...Part 3 BCD Output...
Страница 147: ......