Basic Application MethodsBasic Application Methods
3.2 Monitoring Conveyor Speed Difference: K3HB-R
3-5
■
Settings for the K3HB-R
RUN Level
✽
Check on the status displays.
Initial Setting Level (
L
0
)
Input Adjustment Level
(
L
1
)
Parameter
Characters
Set
value
Remarks
Comparative
set value HH
✽
100
Control example for the following
settings:
HH alarm: 100 rpm
H alarm: 50 rpm
L alarm:
−
50 rpm
LL alarm:
−
100 rpm
Comparative
set value H
✽
50
Comparative
set value L
✽
-50
Comparative
set value LL
✽
-100
Parameter
Characters
Set value
Remarks
Function
func
f4
Rotational difference
Input type A
in-ta
00
No-contact (NO)
Input type B
in-tb
00
No-contact (NO)
Prescale AX
ps.
ax
1.
666
Input A prescale value (
α
)
= 1/60 = 0.01666...
≈
1.666 ...
×
10
−
2
Prescale AY
ps.
ay
10 -2
Prescale BX
ps.
bx
1.
666
Input B prescale value (
α
)
= 1/60 = 0.01666...
≈
1.666 ...
×
10
−
2
Prescale BY
ps.
by
10 -2
Decimal point
position
dp
,,,,,
No decimal point
Comparative
output pattern
out-p
nomal
Standard outputs
Parameter
Characters
Set
value
Remarks
Averaging type
avg-t
smpl
Simple averaging
Averaging times
avg-n
1
Once
Auto-zero time A
at.
za
10.
0
Display is forced to zero
when no pulse is
received for 10 seconds.
Auto-zero time B
at.
zb
10.
0
Содержание K35-2
Страница 2: ......
Страница 24: ...Outline Section 1 Outline 1 8 ...
Страница 25: ...2 1 Preparations Section 2 Preparations 2 1 Mounting 2 2 2 2 Using I O 2 4 ...
Страница 54: ...Basic Application Methods Basic Application Methods Section 3 Basic Application Methods 3 18 ...
Страница 62: ...Initial Setup Section 4 Initial Setup 4 8 ...
Страница 148: ...Functions and Operations Section 5 Functions and Operations 5 86 ...
Страница 149: ...6 1 Troubleshooting Section 6 Troubleshooting 6 1 Error Displays 6 2 6 2 Countermeasures 6 3 ...
Страница 152: ...Troubleshooting Section 6 Troubleshooting 6 4 ...
Страница 185: ......