Functions and Oper
ations
Section 5 Functions and Operations
5-8
Parameter Setting Procedure
A
Press the
M
[MODE] Key several times to display the
comparative set value to be changed.
• One of the values between HH and LL will flash, according to
the displayed comparative set value.
B
Press the
S
[SHIFT] Key to make the SV display flash.
• The setting can be changed when the SV display starts to
flash.
C
Use the
S
[SHIFT] Key and
U
[UP] Key to change the
comparative set value.
D
Press the
M
[MODE] Key to switch to the next parameter.
• The comparative set value set in step C is registered.
123.4
:9999
M
123.4
:9999
L
S
123.4
123.0
L
U
123.4
:9999
LL
M
Содержание K35-2
Страница 2: ......
Страница 24: ...Outline Section 1 Outline 1 8 ...
Страница 25: ...2 1 Preparations Section 2 Preparations 2 1 Mounting 2 2 2 2 Using I O 2 4 ...
Страница 54: ...Basic Application Methods Basic Application Methods Section 3 Basic Application Methods 3 18 ...
Страница 62: ...Initial Setup Section 4 Initial Setup 4 8 ...
Страница 148: ...Functions and Operations Section 5 Functions and Operations 5 86 ...
Страница 149: ...6 1 Troubleshooting Section 6 Troubleshooting 6 1 Error Displays 6 2 6 2 Countermeasures 6 3 ...
Страница 152: ...Troubleshooting Section 6 Troubleshooting 6 4 ...
Страница 185: ......