Functions and Oper
ations
5.2 Setting the Function for the K3HB-P
5-21
■
F6: Interval
Measuring Slit Intervals
• Basic Operation
The number of input A pulses from one input B rising edge to the
next is displayed.
The measurement value can be obtained using the following
formula:
D
=
C
×
α
C
: Number of input A pulses between input B rising edges
α
: Prescale value A
D
: Interval
*TR: Recovery Time
The time required from the end of one measurement until completing
preparations for the next measurement. Allow at least 1 ms.
Referring to the following table, specify the prescale value
corresponding to the desired display unit
.
Na: Number of input A pulses per rotation
π
da: Circumferential length (m) of input A per rotation
A
H
L
PASS
Encoder
Alarm outputs
Operation Configuration (Application)
C
4
C
3
C
2
C
1
Hold
T
R
C
1
×
α
C
2
×
α
C
4
×
α
Input A
Input B
Measurement value No measurement
Measuring time
Measuring time
Measuring time
Measuring time
Not valid
Calculated value
Display unit
Prescale value
(
α
)
Interval
mm
1000
π
da/Na
cm
100
π
da/Na
m
π
da/Na
Содержание K35-2
Страница 2: ......
Страница 24: ...Outline Section 1 Outline 1 8 ...
Страница 25: ...2 1 Preparations Section 2 Preparations 2 1 Mounting 2 2 2 2 Using I O 2 4 ...
Страница 54: ...Basic Application Methods Basic Application Methods Section 3 Basic Application Methods 3 18 ...
Страница 62: ...Initial Setup Section 4 Initial Setup 4 8 ...
Страница 148: ...Functions and Operations Section 5 Functions and Operations 5 86 ...
Страница 149: ...6 1 Troubleshooting Section 6 Troubleshooting 6 1 Error Displays 6 2 6 2 Countermeasures 6 3 ...
Страница 152: ...Troubleshooting Section 6 Troubleshooting 6 4 ...
Страница 185: ......