Ap
pe
nd
ix
1. Troubleshooting
86
G9SX
USER'S GUIDE
G9SX-NS202-
@
/G9SX-NSA222-
@
ERR
indicator
Other
indicator
Fault
Expected causes of the fault
Check points and measures to take
Page
Blinks
---
Fault due to electro-
magnetic disturbance
or of internal circuits
(1) Affected by excessive electromagnetic
disturbance.
(1) Check the disturbance level around the
G9SX and the related system.
---
(2) Failure of the G9SX internal circuit.
(2) Replace the G9SX.
---
Lights
T1 blinks
Fault involved with
safety input 1
(1) Incorrect wiring of safety input 1.
(For example, cross fault detection
mode settings and safety input wiring
do not match).
(1) Check the wiring to T11, T12, T21, T22
and Y1.
63
(2) Wiring to safety input 1 and 24 V or
another I/O terminal short circuited.
(2) Check the wiring to T11 and T12.
---
(3) Short circuit between safety inputs
(when cross fault detection mode is
ON).
(3) Check the wiring to T11, T12, T21 and
T22.
63
(4) Failure in internal circuit for T11 and T12. (4) Replace the G9SX.
---
T2 blinks
Fault involved with
safety input 2
(1) Incorrect wiring of safety input 2.
(For example, cross fault detection
mode settings and safety input wiring
do not match).
(1) Check the wiring to T11, T12, T21, T22
and Y1.
63
(2) Wiring to safety input 2 and 24 V or
another I/O terminal short circuited.
(2) Check the wiring to T21 and T22.
---
(3) Short circuit between safety inputs
(when cross fault detection mode is
ON).
(3) Check the wiring to T11, T12, T21 and
T22.
63
(4) Failure in internal circuit for T21 and T22. (4) Replace the G9SX.
---
NS blinks
Fault in Non-contact
Door Switch input
(1) Wiring to the Non-contact Door Switch
input and 24 V or another I/O terminal
short circuited.
(1) Check the wiring to D1 and D2.
66
(2) Incorrect wiring of Non-contact Door
Switch inputs in series connection.
(2) Check the wiring to the D40A.
66
Failure in internal
circuit
(3) Non-contact Door Switch failed.
(3) Replace the D40A.
---
(4) Failure in internal circuit for D1 and D2. (4) Replace the G9SX.
---
FB blinks
Fault involved with
feedback/reset
inputs
(1) Incorrect feedback/reset input wiring.
(1) Check the wiring to T31, T32, and T33.
62
Fault in Expansion
Unit
(2) Connecting cable to Expansion Unit or
terminating connector disconnected.
(2) Check the connecting cable to the
Expansion Unit and the connection of
the terminating connector.
69
Abnormal supply
voltage to
Expansion Unit
(3) Voltage fluctuation caused by
insufficient supply voltage current
capacity.
(3) Change to a power supply with a
greater current capacity.
---
(4) Supply voltage outside the rated value.
(4) Connect to a supply voltage of 24 VDC
-15% to +10%.
---
Failure in internal
circuit
(5) Failure in internal circuit for T31, T32
and T33.
(5) Replace the G9SX.
---
(6) Expansion Unit relay contact or internal
circuit failed.
(6) Replace the Expansion Unit.
---
EI blinks
Fault involved with
instantaneous safety
outputs
(1) Instantaneous safety outputs short
circuited.
(1) Check the wiring to S14 and S24.
---
(2) Instantaneous safety outputs and 24 V,
0 V, or another I/O terminal short
circuited.
(2) Check the wiring to S14 and S24.
---
Fault involved with
logical AND
connection outputs
(3) Logical AND connection outputs and
24 V, 0 V, or another I/O terminal short
circuited.
(3) Check the wiring to L1.
---
Abnormal ambient
temperature
(4) The environment exceeds the
permissible ambient operating
temperature.
(4) Check the ambient temperature and
spacing around the G9SX.
77
Failure in internal
circuit
(5) Failure in internal circuit for S14 and
S24.
(5) Replace the G9SX.
---
(6) Failure in internal circuit for L1.
(6) Replace the G9SX.
---
Содержание G9SX Series
Страница 50: ...MEMO 50 G9SX USER S GUIDE ...
Страница 95: ...G9SX USER S GUIDE 95 Precautions Precautions ...
Страница 101: ...MEMO G9SX USER S GUIDE 101 ...
Страница 102: ...MEMO 102 G9SX USER S GUIDE ...