Wi
ri
ng
a
nd
Se
tu
p
Section
3
2. Functions, Wiring and Settings
58
G9SX
USER'S GUIDE
3. Logical AND Connection Combinations
( 1 ) One logical AND connection output from an Advanced Unit G9SX-AD can be logical AND connected to up to
four Advanced Units.
( 2 ) Two logical AND outputs from a Basic Unit G9SX-BC can be logical AND connected to up to eight Advanced
Units.
( 3 ) Two logical AND outputs from an Advanced Unit G9SX-ADA can be logical AND connected to up to eight
Advanced Units.
( 4 ) Any Advanced Unit with logical AND input can be logical AND connected to Advanced Units on up to five tiers.
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-BC
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-ADA
G9SX-AD
G9SX-AD
G9SX-AD
Advanced Unit
or Basic Unit
G9SX-AD
G9SX-AD
G9SX-AD
G9SX-AD
Содержание G9SX Series