A
p
plica
tion Examples
Section
1
1. Partial control of machine
16
G9SX
USER'S GUIDE
■
Wiring Example
Setup
(For details, refer to Section 3.)
G9SX-BC: Manual reset, Cross fault detection mode: ON (Category 4 Wiring)
G9SX-AD: Auto reset, Cross fault detection mode: ON (Category 4 Wiring), Logical AND connections,
OFF-delay time setting
Wiring Example
S14
A2
S24
L1 L2
X1 X2
T11
A1
T12 T21 T22 T31 T32 T33 Y1
KM2
KM1
S2
12
11
21
22
+24V
M1
KM2
KM 1
S1
+24V
NC
GND
G9SX-BC202
(Unit A)
Control circuit
S34
4
M3
KM6
KM5
Open
S4
Feedback Loop
S14
A2
S24 S34 S44 S54 L1 X1 X2
T11
A1
T12 T21 T22 T31 T32 T33 Y1
T41 T42
+24V
+24V
KM5 KM6
OFF
AND
NC
GND
G9SX-AD322-T15
(Unit C)
Control circuit
KM6
KM5
Motor controller
Motor controller
S34
4
M2
KM4
KM3
Open
S3
PLC etc.
Feedback Loop
S14
A2
S24 S34 S44 S54 L1 X1 X2
T11
A1
T12 T21 T22 T31 T32 T33 Y1
T41 T42
+24V
+24V
KM3 KM4
OFF
AND
NC
GND
G9SX-AD322-T15
(Unit B)
Control circuit
KM4
KM3
Feedback Loop
KM1 KM2
Motor controller
(Operation command)
Motor controller
(Operation command)
PLC etc.
PLC etc.
S1 : Emergency Stop Switch
S2 : Reset switch
S3, S4 : Safety Door Switch
KM1 to KM6 : Contactor
M1 to M3 : 3-phase motor
Note:
This example corresponds to category 4.
Содержание G9SX Series