2-11 Confirming Settings
Settings for the G9SX can be checked by the orange indicators for approx. 3 seconds after the power is turned ON.
During this settings indication period, the ERR indicator will light, however the auxiliary error output will remain OFF.
G9SX-AD/-ADA/-BC/-NS/-NSA
Note:
Except for the G9SX-BC and G9SX-NS.
G9SX-GS
Indicator
Item
Setting position
Indicator
status
Setting mode
Setting status
T1
Cross fault detection
mode
Y1 terminal
Lit
Detection mode
Y1 = open
Not lit
Non-detection mode
Y1 = 24 VDC
FB
Reset mode
T33 or T32
terminal
Lit
Manual reset mode
T33 = 24 VDC
Not lit
Auto reset mode
T32 = 24 VDC
AND
(AND1,
AND2)
Logical AND connection
input mode (See note.)
Logical AND
connection preset
switch
Lit
Enable logical AND input
"AND"
Not lit
Disable logical AND input
"OFF"
Indicator
Item
Setting position
Indicator
status
Setting mode
Setting status
T1
Cross fault detection
mode for safety input A
Y1 terminal
Lit
Enabled
Y1 = open
Not lit
Disabled
Y1 = 24 VDC
T6
Cross fault detection
mode for safety input B
Y2 terminal
Lit
Enabled
Y2 = open
Not lit
Disabled
Y2 = 24 VDC
FB
Reset mode
T33 or T32
terminal
Lit
Manual reset mode
T33 = 24 VDC
Not lit
Auto reset mode
T32 = 24 VDC
AND
Logical AND connection
input mode
Logical AND
connection preset
switch
Lit
Enabled
"AND"
Not lit
Disabled
"OFF"
UA, UB
Switching Function
Switching Function
setting switch
Lit
Manual switching
"Manual"
Not lit
Auto switching
"Auto"