5 - 53
5 Setup and Wiring
Vision System FZ5 series Hardware Setup Manual (Z423)
5
-8 In
stallation
in a C
ontrol Pan
el
5
5-
8-6 F
Z5-
L Series
Precautions for Correct Use
Ambient Temperature
• Install and store the product in a location that meets the following conditions:
• Surrounding temperature of 0 to 50°C (-20 to +65°C in storage)
• Relative humidity of between 35 to 85%RH
• Do not let the ambient temperature exceed 50°C (122°F).
• Provide a forced-air fan cooling or air conditioning if the ambient temperature is near 50°C
(122°F) so that the ambient temperature never exceeds 50°C (122°F).
Installation method
• For good heat dissipation, install the product only in the position shown below so as not to
block the ventilation holes.
• Do not install the product in the following positions.
• For good ventilation, provide a clearance of 50 mm or more above the sensor controller away
from other devices in the normal floor mounting. For the right and left sides, provide a clear-
ance of 30 mm or more, and for the back side, 15 mm or more. These clearances are also
required when mounting multiple sensor controllers side by side. For the back mounting, the
back-side clearance of 15 mm is nor required.
5-8-6
FZ5-L Series
Содержание fz5 series
Страница 8: ...Manual Structure 6 Vision System FZ5 series Hardware Setup Manual Z423...
Страница 50: ...1 Confirm the Package 1 14 Vision System FZ5 series Hardware Setup Manual Z423...
Страница 162: ...3 Configuration 3 100 Vision System FZ5 series Hardware Setup Manual Z423...
Страница 285: ......