5 - 9
5 Setup and Wiring
Vision System FZ5 series Hardware Setup Manual (Z423)
5-3
Senso
r C
o
n
troller In
stallation
5
5-
3-2 F
H-10
00/2000/3000
/5000 Series
Connecting of Sensor Controller’s terminal block in order to connect package the terminal block con-
nector (male; FH-XCN).
Use the specified wire size (AWG10 to 16) and keep the power supply wires as short as possible (Max. 2 m).
1
Insert the end of the signal line (electric wire) into the terminal block connector (male), and tighten the
three screws on the connector top to fix the wire. Recommended tightening torque: 0.7-0.8 N•m
2
Connect the wire and power source to the terminal block connector (male) depending on the
indicated terminal block connector.
3
Insert the terminal block connector (male) to the terminal block connector (female) of Sensor
Controller.
4
Tightens and fix the left and right screws for the terminal block connector (male).
(Recommended tightening torque: 0.7 N•m to 0.8 N•m)
Connection of Terminal Block of FH-1000/2000/3000/5000 Series
Indicate of terminal
block connector
Function
+
Connect the DC output positive (+V) of 24 VDC power.
-
Connect the DC output positive (-V) of 24 VDC power.
Connect the earth.
Terminal block connector (female)
Terminal block connector (male)
14.7
7.64
22.81
19.7
35.3
7.62
7.62
(Unit: mm)
Содержание fz5 series
Страница 8: ...Manual Structure 6 Vision System FZ5 series Hardware Setup Manual Z423...
Страница 50: ...1 Confirm the Package 1 14 Vision System FZ5 series Hardware Setup Manual Z423...
Страница 162: ...3 Configuration 3 100 Vision System FZ5 series Hardware Setup Manual Z423...
Страница 285: ......