58
Allocating I/O from the Configurator
Section 4-3
Note
1.
Can be used with TC2, but not with TC4.
2.
Monitoring can be performed for up to four G3ZA or G3PW Power Control-
lers per Temperature Controller. Each channel of the Temperature Control-
ler corresponds to one G3ZA or G3PW Power Controller. (Example: ch1
→
G3ZA1)
Parameters That Can
Be Changed during
Operation (TC4 and
TC2)
These parameters, such as the SP, PID, and alarm values, can be changed
during operation of the Temperature Controller.
Yes
No
G3ZA CH3 Status (See note 2.)
77 (4D hex)
Yes
No
G3ZA CH4 Status (See note 2.)
78 (4E hex)
Yes
No
G3ZA CH5 Status (See note 2.)
79 (4F hex)
Yes
No
G3ZA CH6 Status (See note 2.)
80 (50 hex)
Yes
No
G3ZA CH7 Status (See note 2.)
81 (51 hex)
Yes
No
G3ZA CH8 Status (See note 2.)
82 (52 hex)
Yes
No
G3ZA CH1 Heater ON Current Monitor
G3PW Current Monitor (See note 2.)
83 (53 hex)
Yes
No
G3ZA CH2 Heater ON Current Monitor
(See note 2.)
84 (54 hex)
Yes
No
G3ZA CH3 Heater ON Current Monitor
(See note 2.)
85 (55 hex)
Yes
No
G3ZA CH4 Heater ON Current Monitor
(See note 2.)
86 (56 hex)
Yes
No
G3ZA CH1 Heater OFF Current Monitor
(See note 2.)
87 (57 hex)
Yes
No
G3ZA CH2 Heater OFF Current Monitor
(See note 2.)
88 (58 hex)
Yes
No
G3ZA CH3 Heater OFF Current Monitor
(See note 2.)
89 (59 hex)
Yes
No
G3ZA CH4 Heater OFF Current Monitor
(See note 2.)
90 (5A hex)
Allo-
cated
in IN
Area
Allo-
cated
in OUT
Area
Parameter name
Allocation number
for expansion remote
I/O
Allo-
cated
in IN
Area
Allo-
cated
in OUT
Area
Parameter name
Allocation number
for expansion remote
I/O
Yes
Yes
Present Bank Set Point
27 (1B hex)
Yes
Yes
Present Bank Proportional Band
28 (1C hex)
Yes
Yes
Present Bank Integral Time
29 (1D hex)
Yes
Yes
Present Bank Derivative Time
30 (1E hex)
Yes
Yes
Present Bank SP Ramp Rise Value
31 (1F hex)
Yes
Yes
Present Bank SP Ramp Fall Value
32 (20 hex)
Yes
Yes
Present Bank Manual Reset Value
33 (21 hex)
Yes
Yes
Present Bank Cooling Coefficient
34 (22 hex)
Yes
Yes
Present Bank Dead Band
35 (23 hex)
Yes
Yes
Present Bank Alarm Value
36 (24 hex)
Yes
Yes
Present Bank Alarm Upper Limit Value 1
37 (25 hex)
Yes
Yes
Present Bank Alarm Lower Limit Value 1
38 (26 hex)
Yes
Yes
Present Bank Alarm Value 2
39 (27 hex)
Yes
Yes
Present Bank Alarm Upper Limit Value 2
40 (28 hex)
Yes
Yes
Present Bank Alarm Lower Limit Value 2
41 (29 hex)
Содержание EJ1 - 07-2008
Страница 1: ...DeviceNet Communications Unit for EJ1 Temperature Controllers Cat No H155 E1 02 OPERATION MANUAL...
Страница 2: ...DeviceNet Communications Unit for EJ1 Temperature Controllers Operation Manual Revised July 2008...
Страница 3: ...iv...
Страница 19: ...xx...
Страница 33: ...14 Initial Temperature Controller Settings Section 1 4...
Страница 53: ...34 Wiring the Temperature Controllers Section 3 4...
Страница 101: ...82 Ladder Programming Examples Section 4 6...
Страница 143: ...124 Sending Explicit Messages Section 6 5...
Страница 155: ...136 Message Communications Characteristics Section 7 2...
Страница 163: ...144 Maintenance Section 8 2...
Страница 189: ...170 Allocation Numbers for Configurators Manufactured by Other Companies Appendix B...
Страница 197: ...178 Index...