57
Allocating I/O from the Configurator
Section 4-3
Monitor Parameters
(TC4 and TC2)
These parameters are for monitoring PV, SP, and other data of the Tempera-
ture Controller.
Allo-
cated
in IN
Area
Allo-
cated
in OUT
Area
Parameter name
Allocation number
for expansion remote
I/O
Yes
No
Device A Status
1 (1 hex)
Yes
No
Configuration Error A Status
3 (3 hex)
Yes
No
Configuration Error B Status
4 (4 hex)
Yes
No
Internal Communications Error Status
5 (5 hex)
Yes
No
I/O Error Status
6 (6 hex)
Yes
No
I/O Alarm A Status (See note 1.)
7 (7 hex)
Yes
No
I/O Alarm B Status (See note 1.)
8 (8 hex)
Yes
No
I/O Notification A Status (See note 1.)
9 (9 hex)
Yes
No
Error Channel A Status
10 (A hex)
Yes
No
Basic Unit/Expand Unit Error
11 (B hex)
Yes
No
Basic Unit/Expand Unit Alarm
12 (C hex)
Yes
No
Output Status
13 (D hex)
Yes
No
Device B Status
14 (E hex)
Yes
No
Process Value
15 (F hex)
Yes
No
Channel Status
16 (10 hex)
Yes
No
Channel Alarm Status
17 (11 hex)
Yes
No
Internal SP
18 (12 hex)
Yes
No
Local SP Monitor
19 (13 hex)
Yes
No
Remote SP Monitor
20 (14 hex)
Yes
No
Bank No. Monitor
21 (15 hex)
Yes
No
MV Monitor (Heating)
22 (16 hex)
Yes
No
MV Monitor (Cooling)
23 (17 hex)
Yes
No
Decimal Point Monitor
24 (18 hex)
Yes
No
Heater Current Value Monitor
(See note 1.)
25 (19 hex)
Yes
No
Leakage Current Value Monitor
(See note 1.)
26 (1A hex)
Yes
No
G3ZA CH1 Control Variable Monitor
G3PW Output Variable Monitor
(See note 2.)
67 (43 hex)
Yes
No
G3ZA CH2 Control Variable Monitor
(See note 2.)
68 (44 hex)
Yes
No
G3ZA CH3 Control Variable Monitor
(See note 2.)
69 (45 hex)
Yes
No
G3ZA CH4 Control Variable Monitor
(See note 2.)
70 (46 hex)
Yes
No
G3ZA CH5 Control Variable Monitor
(See note 2.)
71 (47 hex)
Yes
No
G3ZA CH6 Control Variable Monitor
(See note 2.)
72 (48 hex)
Yes
No
G3ZA CH7 Control Variable Monitor
(See note 2.)
73 (49 hex)
Yes
No
G3ZA CH8 Control Variable Monitor
(See note 2.)
74 (4A hex)
Yes
No
G3ZA CH1 Status (See note 2.)
G3PW Status
75 (4B hex)
Yes
No
G3ZA CH2 Status (See note 2.)
76 (4C hex)
Содержание EJ1 - 07-2008
Страница 1: ...DeviceNet Communications Unit for EJ1 Temperature Controllers Cat No H155 E1 02 OPERATION MANUAL...
Страница 2: ...DeviceNet Communications Unit for EJ1 Temperature Controllers Operation Manual Revised July 2008...
Страница 3: ...iv...
Страница 19: ...xx...
Страница 33: ...14 Initial Temperature Controller Settings Section 1 4...
Страница 53: ...34 Wiring the Temperature Controllers Section 3 4...
Страница 101: ...82 Ladder Programming Examples Section 4 6...
Страница 143: ...124 Sending Explicit Messages Section 6 5...
Страница 155: ...136 Message Communications Characteristics Section 7 2...
Страница 163: ...144 Maintenance Section 8 2...
Страница 189: ...170 Allocation Numbers for Configurators Manufactured by Other Companies Appendix B...
Страница 197: ...178 Index...