Chapter 3
3-12
Operation
3-5
Adjustment Mode
• Switching from RUN mode to adjustment mode is possible at any time by pressing the Enter Key for
1 second or longer.
• Switching from adjustment mode back to RUN mode is possible by pressing the Enter Key for
1 second or longer when any of the following adjustment items is being displayed: SP1 to SP4,
ACC, DEC, or LOD. If a set value is being displayed, press the Enter Key to display the setting item
name.
3-5-1 Setting Frequency References 1 to 4
• Four frequency references can be remembered internally in the Inverter.
• The frequency references 1 to 4 are set in increments of 0.1 Hz for less than 100 Hz and in incre-
ments of 1 Hz for 100 Hz or greater.
• Frequency references 1 to 4 are enabled when P11 (frequency reference selection) is set to MSP
(multi-step speed reference).
■
Relation between Control Circuit Terminals and Frequency Reference
Multi-step speed reference 0 (SS0) and multi-step speed reference 1 (SS1) can be used together to
select one of the following frequency references.
Note
Multi-step speed references are supported only for Standard Models.
SP1
Frequency reference 1
Changes during
operation
Yes
Setting range
0.0 to 120 (Hz)
Setting unit
0.1 Hz
Default setting
10.0
SP2
Frequency reference 2
Changes during
operation
Yes
Setting range
0.0 to 120 (Hz)
Setting unit
0.1 Hz
Default setting
0.0
SP3
Frequency reference 3
Changes during
operation
Yes
Setting range
0.0 to 120 (Hz)
Setting unit
0.1 Hz
Default setting
0.0
SP4
Frequency reference 4
Changes during
operation
Yes
Setting range
0.0 to 120 (Hz)
Setting unit
0.1 Hz
Default setting
0.0
Multi-step speed reference
SS0
SS1
Frequency reference 1 (SP1)
OFF
OFF
Frequency reference 2 (SP2)
ON
OFF
Frequency reference 3 (SP3)
OFF
ON
Frequency reference 4 (SP4)
ON
ON
Содержание EasySpeed 3G3JE
Страница 1: ...3G3JE Compact Simplified Inverters Cat No I547 E1 02 USER S MANUAL...
Страница 3: ...USER S MANUAL 3G3JE Compact Simplified Inverters...
Страница 18: ...Table of Contents XVI...
Страница 19: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature...
Страница 23: ...Chapter 2 Design 2 1 Installation 2 2 Wiring...
Страница 86: ...Chapter 3 3 26 Operation...
Страница 100: ...Chapter 4 4 14 Maintenance Operations...
Страница 101: ...Chapter 5 Specifications 5 1 Inverter Specifications 5 2 Option Specifications...
Страница 112: ...Chapter 5 5 12 Specifications...
Страница 113: ...Chapter 6 Parameter Tables...
Страница 118: ...Chapter 6 6 6 Parameter Tables...
Страница 119: ...Chapter 7 Appendix 7 1 Selecting the Inverter 7 2 Precautions on Using the Inverter for a Motor...
Страница 130: ...Chapter 7 7 12 Appendix...
Страница 132: ...R 2 Revision History...