Chapter 3
3-10
Operation
3-4-2 Selecting the Item to be Displayed
■
Changing the Display Item
• The Mode Key can be pressed to change the display item in the order shown below.
• The display item can be change during operation or when operation is stopped.
Note
The
@
RVS indicator will not light when forward operation is set
and
fwd
will be displayed on the
data display
.
If reverse operation is set, the
@
RVS indicator will light and
rev
will be displayed
on the data display.
3-4-3 Changing the Frequency Reference
■
Range for Changing the Frequency Reference
• The frequency reference is set in increments of 0.1 Hz for less than 100 Hz and in increments of
1 Hz at 100 Hz or higher. The setting range for the frequency reference is between the frequency
reference upper limit (P07) and the frequency reference lower limit (P08) set in the initial settings
mode. (Set the frequency reference upper limit and frequency reference lower limit in initial settings
mode.)
■
Setting the Frequency Reference
• The frequency reference can be set during operation or while operation is stopped.
Display
Key
sequence
Indicator
Display
example
Explanation
Frequency ref-
erence
@
Hz set
The entire display and simplified-LED indi-
cators will light (except for the COM indica-
tor) when the power supply is turned ON.
The present frequency reference will be
displayed on the data display.
Output fre-
quency
@
Hz out
When the Mode Key is pressed while the
@
Hz set indicator is lit, the output frequency
will be displayed. At the same time the
@
Hz out indicator will light.
Output current
@
A
When the Mode Key is pressed while the
@
Hz out indicator is lit, the present output
current will be displayed. At the same time
the
@
A indicator will light.
Accumulated
operating time
@
Kh
When the Mode Key is pressed while the
@
A indicator is lit, the present accumulated
operating time will be displayed. At the
same time the
@
Kh indicator light will light.
Forward/
reverse opera-
tion selection
None (See
note.)
(
@
RVS)
When the Mode Key is pressed while the
@
Kh indicator is lit, the present direction of
rotation will be displayed. No indicator will
light.
60.0
0.0
0.0
0.0
fwd
Содержание EasySpeed 3G3JE
Страница 1: ...3G3JE Compact Simplified Inverters Cat No I547 E1 02 USER S MANUAL...
Страница 3: ...USER S MANUAL 3G3JE Compact Simplified Inverters...
Страница 18: ...Table of Contents XVI...
Страница 19: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature...
Страница 23: ...Chapter 2 Design 2 1 Installation 2 2 Wiring...
Страница 86: ...Chapter 3 3 26 Operation...
Страница 100: ...Chapter 4 4 14 Maintenance Operations...
Страница 101: ...Chapter 5 Specifications 5 1 Inverter Specifications 5 2 Option Specifications...
Страница 112: ...Chapter 5 5 12 Specifications...
Страница 113: ...Chapter 6 Parameter Tables...
Страница 118: ...Chapter 6 6 6 Parameter Tables...
Страница 119: ...Chapter 7 Appendix 7 1 Selecting the Inverter 7 2 Precautions on Using the Inverter for a Motor...
Страница 130: ...Chapter 7 7 12 Appendix...
Страница 132: ...R 2 Revision History...