1-2
Operating Procedure
This section describes the procedure to construct a motion control system by using the Motion Con-
troller.
No.
Step
Description
Reference
1
Preparation for
work
Check for specifi-
cation compatibili-
ty
Check compatibility with specifications
of each Unit.
•
General specifications
•
Mounting direction
Selection of pe-
ripheral devices
Select peripheral devices to be used
with the Motion Controller.
Preparation of
Support Software
Procure and install the Support Soft-
ware required for the system.
2
Mounting and
wiring of the
Motion Control-
ler
Mounting
Mount the Motion Controller.
•
Connecting adjacent Units
•
Mounting to DIN Track
Address switch
setting
Set the address switches for the CK3W
Units.
Wiring
Perform Motion Controller wiring.
3
Settings and
wiring of the
EtherCAT slave
hardware
Node address
settings
Use the hardware switches on all of the
EtherCAT slaves in the network to set
the node addresses.
Refer to the manual for the Ether-
CAT slave.
Mounting
Mount EtherCAT slaves.
Refer to the manual for the Ether-
CAT slave.
Wiring
Wire EtherCAT slaves.
•
Wiring of the unit power supply
•
I/O wiring
Refer to the manual for the Ether-
CAT slave.
4
Installing EtherCAT Communications
Cables
Perform wiring for the EtherCAT com-
munications cables.
5-2-1 Laying the EtherCAT Net-
work
5
Turn ON the power supply to Ether-
CAT slaves.
Turn on the power to the devices con-
figuring the system.
6
Construction of
the EtherCAT
network
Installation of ESI
files
Install the ESI files of EtherCAT slaves
to be connected.
Refer to the
Power PMAC IDE
User Manual (Cat. No. O016)
for
details.
For information on the ESI file, re-
fer to the manual for the EtherCAT
slave.
EtherCAT slave
settings
Configure the EtherCAT communica-
tions settings.
Then, create an ENI file used to down-
load the configured settings to the Mo-
tion Controller.
Refer to the
Power PMAC IDE
User Manual (Cat. No. O016)
for
details.
Activation of the
EtherCAT network
Use Power PMAC IDE to download the
ENI file to the Motion Controller.
Make sure that the ENI file has been
correctly downloaded, and then activate
the EtherCAT network.
Refer to the
Power PMAC IDE
User Manual (Cat. No. O016)
for
details.
1 Introduction to Motion Controllers
1-5
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
1-2 Operating Procedure
1
Содержание CK3M Series
Страница 6: ...Manual Structure 4 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 236: ...6 Troubleshooting 6 22 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 242: ...7 Inspection and Maintenance 7 6 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 284: ...Appendices A 42 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 285: ...I Index I 1 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036 I...
Страница 287: ......