Pin No.
XY
Z
Signal
Input/Output
Signal
Input/Output
1
XY-IN+
Input
Z-IN+
Input
2
XY-OUT+ Output
Z-OUT+ Output
3
NC
-
NC
-
4
NC
-
NC
-
5
NC
-
NC
-
6
XY-IN-
Input
Z-IN-
Input
7
XY-OUT-
Output
Z-OUT-
Output
8
NC
-
NC
-
9
NC
-
NC
-
10
NC
-
NC
-
11
NC
-
NC
-
12
NC
-
NC
-
13
NC
-
NC
-
14
NC
-
NC
-
15
NC
-
NC
-
Shell
Shield
Shield
Dedicated Cable
The dedicated cable for wiring to the Galvo Scanner connector is provided as an option.
The Galvo Scanner connection side has discrete wires.
Perform wiring to match the Galvo Scanner specifications.
The cable model is as shown below.
Type
Model
Length
For Galvo Scanner CK3W-CAG03A 3 m
Shield
3000
35
24AWG × 6 Pairs
6
1
5
10
15
11
5 Wiring
5-47
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
5-7 Laser Interface Unit
5
5-7-1
Galvo Scanner Connector Wiring
Содержание CK3M Series
Страница 6: ...Manual Structure 4 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 236: ...6 Troubleshooting 6 22 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 242: ...7 Inspection and Maintenance 7 6 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 284: ...Appendices A 42 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 285: ...I Index I 1 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036 I...
Страница 287: ......