7-2
Maintenance Procedures
This section describes the procedures to back up the data in the CPU Unit and to replace the Unit.
Use Power PMAC IDE Ver.4.0 or a higher version.
7-2-1
Unit Replacement Precautions
If you find any faulty Units during inspection, replace the Unit according to the following points.
• Do not replace a Unit until the power is turned OFF.
• After replacement, check the new Unit to ensure that there are no errors.
• If you return a faulty unit for repair, describe the problem in as much detail as possible, enclose this
description with the Unit, and request repairs.
7-2-2
Backup
Store the project file and the EtherCAT ENI file so that the data can be restored when a failure or other
problems occur.
If you are not using EtherCAT, saving the ENI file is not necessary.
7-2-3
Unit Replacement
Procedure to Replace a CPU Unit
The following describes the basic replacement procedure for the CPU Unit.
No.
Step
Description
Reference
1
Turn OFF power
to the devices
Turn OFF power to the Motion Controller.
Take measures to ensure that there are no effects on the peripheral
devices, and then turn OFF power to the Motion Controller.
-
2
Disconnect ca-
bles
Disconnect the cables connected to the CPU Unit.
-
3
Replace the CPU
Unit
Replace the CPU Unit with a new Unit, connect the cables, and turn
ON power to the Motion Controller and EtherCAT equipment.
-
4
Connect with IDE Connect the CPU Unit and the Power PMAC IDE online through
Ethernet.
-
5
Initialize
In the terminal window, input the re-initialization command ($$$***),
and initialize the CPU Unit.
-
6
Read the Ether-
CAT ENI file
In Power PMAC IDE, click
Delta Tau
–
Tools
–
System Setup
–
Master[0] Deactivated
in order.
Click the
Browse
button, and read the backed-up ENI file into Power
PMAC IDE.
Only when us-
ing EtherCAT
7
Write the Ether-
CAT ENI file
Click the
Download ENI file
button, and write the ENI file to the
CPU Unit.
Only when us-
ing EtherCAT
8
Read the project
file
Read out the backed-up project file in Power PMAC IDE.
The
EtherNet/IP
settings are
contained in
the project file.
7 Inspection and Maintenance
7-4
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
Содержание CK3M Series
Страница 6: ...Manual Structure 4 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 236: ...6 Troubleshooting 6 22 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 242: ...7 Inspection and Maintenance 7 6 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 284: ...Appendices A 42 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 285: ...I Index I 1 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036 I...
Страница 287: ......