3-7
Laser Interface Unit
This section describes the Laser Interface Unit.
3-7-1
Models and Specifications
Models and Outline of Specifications
The models and outline of specifications are given below.
Unit type
Model
Communications method
Laser output
Laser Interface Unit CK3W-GC1100 XY2-100
PWM output
CK3W-GC1200
PWM output, TCR output
CK3W-GC2100 SL2-100
PWM output
CK3W-GC2200
PWM output, TCR output
Specifications
XY2-100 Inter-
face
16 bits, 18 bits, or 20 bits
Clock output frequency
2 MHz
Data refresh period
10 µs
Maximum transmission
distance
10 m
Isolation method
Not isolated (between internal circuit and XY2-100 circuit)
3 Configuration Units
3-66