37
2-7
Function/Constant List
First Functions (Constant Nos. 0 to 19)
Function
No.
Name
Description
Initial
setting
User
set
values
See
page
Password
setting
0
Password
0: Password (No. 00) setting/reading and
first function (constant Nos. 1 to 19)
reading possible
1
44
Constant
write-pro-
tect
1: First function (constant Nos. 0 to 19)
setting/reading possible
2: First and second function (constant
Nos. 0 to 29) setting/reading possible
Constant
group
selection
3: First, second and third function (con-
stant Nos. 0 to 59) setting/reading pos-
sible
5: First, second and third function (con-
stant Nos. 0 to 69) setting/reading pos-
sible
Fault con-
tents clear
6: Fault record clear
Constant
initializa-
tion
8: Initialize (multifunction terminal: initial
value setting)
9: Initialize (3-wire sequence)
Operation
method
selection
1
Run signal
selection 1
1
st
digit
= 0: Main frequency reference-
external terminals 8 and 9
inputs
1: Main frequency reference-
operator Fxxxx
2
nd
digit = 0: Run by external terminal
run command
1: Run by operator run com-
mand
0011
1
st
digit
4
th
digit
45
Stopping
method
selection
3
rd
digit
= 0: Deceleration to a stop
1: Coasting to a stop
V/f pattern
setting
Output volt-
age limiter
selection
4
th
digit
= 0: With output voltage limiter
1: Without output voltage lim-
iter
47
V/f char-
acteristic
2
Maximum fre-
quency
Setting unit: 0.1 Hz, setting range: 50.0 to
400.0 Hz
60.0 Hz
45
setting
3
Maximum
voltage
Setting unit: 0.1 V, setting range: 0.1 to
255.0 V
200.0 V
(Note 1)
45
4
Maximum
voltage fre-
quency (base
frequency)
Setting unit: 0.1 Hz, setting range: 0.1 to
400.0 Hz
60.0 Hz
45
5
Intermediate
output fre-
quency
Setting unit: 0.1 Hz, setting range: 0.1 to
400.0 Hz
1.5 Hz
45
6
Intermediate
output fre-
quency volt-
age
Setting unit: 0.1 V, setting range: 0.1 to
255.0 V
12.0 V
(Note 1)
45
Function/Constant List
Section 2-7