89
3.
If you wish to connect over a network, you must check the box “Connect over Ethernet”. When you do this,
the parameters required for direct serial or dial-in via modem will be grayed out. Then, only the TCP/IP
address of the Omnia that you wish to connect to must be entered. Note: If you are connecting via Direct
Serial or Modem, you should not check the “Connect over Ethernet” box!
4.
If connecting via Direct Serial or Modem, then select the COM port that you wish to use on your PC. This
COM port should be configured in Windows for the highest baud rate that your PC will support, but in any
case, should be set to at least 57,600 bps.
5.
If connecting via Direct Serial, no other information is required.
6.
If connecting via Modem, in the “Phone #” box, enter the telephone number of the modem that is
connected to the Omnia at the remote site. Any characters present in the “Phone #” box signal the Omnia
Remote program to attempt a connection via modem!
If you need to use a Modem Initialization string, you may enter it into the “Modem Init” string box. If you require a
modem initialization string and feel more comfortable building the entire connect string within the “Phone #” box
you may do this. See “Using Custom Modem Initialization Strings” for more information.
If your connection attempt times out before the Omnia can answer, you can increase the value (in seconds) of the
“Connection Timeout” setting. This value sets the amount of time the software will wait for the carrier tone from
the Omnia’s modem before timing out and hanging up the computer’s modem.
Omnia Remote Control supports a wide variety of Hayes command set compatible modems. If you have difficulty
using your modem, you may call Omnia Customer Support for assistance, but please gather as much information
about your modem as possible before doing so.
On the Omnia Side...
Remote Control Using the Optional Omnia PCMCIA Modem
Before use, ensure that the Omnia-approved PCMCIA modem card is fully inserted into the lower PC Card slot on
the back of the Omnia. Press on the modem card's “XJACK” connector to extend the modular telephone jack. Using
a standard RJ-11cable, connect your telephone line to the Omnia modem. Make a note of the telephone number
corresponding to this line, as you will need it later when you configure the Omnia Remote Control program.
Note: The modem card can only be safely installed and removed when the Omnia's power is off. Only the PCMCIA
modem card supplied by Telos Omnia has been tested and approved by Telos Omnia. We cannot ensure correct
operation of any other modem card with the Omnia-6EX, nor can we provide support for such non-approved cards.
Remote Control Using a External Hayes Compatible Modem
The Omnia supports nearly every Hayes command set compatible modem available. Please note that in order to
support the widest possible variety of externally connected serial devices the Omnia-6EX's RS-232 port does not
support hardware or software handshaking. This is of no concern, and we are aware of no instances where this has
prevented an externally connected modem from operating properly. The externally connected modem will need to
auto-detect one of the Omnia's three rear panel serial port's baud rates (9,600, 19200, and 57,600). Because the
Omnia and the modem are both DCE devices, you will need to use a crossover (null modem) cable between them.
Содержание Omnia-6EX
Страница 113: ...Omnia 6ex Use and Operation Manual V 1 20 113 Omnia 6...
Страница 114: ...Omnia 6ex Use and Operation Manual V 1 20 114...