background image

12 | 

P a g e

  END DEVICE READINGS AND CONFIGURATION 

This section details how to view, log and chart data received from End Devices. Turn on and 
configure any End Devices now. Confirm that all End Devices are set to the same Network ID 
as the desired ZW-REC. Also ensure each End Device has a different Device ID selected. If an 
End Device is running, it needs to be reset after changes to the Device ID or Network ID. 
Power on all End Devices now. If existing End Devices are running they may need to be reset 
now. 
Please refer to the End Device user manual for detailed instructions on setting Network IDs 
and Device IDs. 

The ZW-REC can display a NID chart to help configure zSeries and zwSeries End 
Devices. Refer to 

Section 5.1

 for more information. 

4.1  End Device Readings Page 

When logging into the ZW-REC the End Device Readings page is displayed. The readings page 
shows the current sensor data from all connected End Devices. When an End Device turns on 
it enters active scan mode and search for a receiver. When the ZW-REC is found the Blue 
Wireless Link Indicator on the End Device flashes once and turns off. The Link Indicator flashes 
again each time a reading is transmitted. Once an End Device finishes connecting to the ZW-
REC it is automatically added to the reading page. 

The readings page shows the End Device ID, Name and Status followed by readings from any 
connected sensors. End Device Status will change from Good to Lost if an End Device misses 
three transmissions in a row. 
The Sequence Number is transmitted by the End Device and incremented with each 
transmission. An increasing sequence number shows that the web page is getting fresh data 

Figure 7.   End Device Readings (Populated) 

Содержание ZW-REC

Страница 1: ...e mail info omega com For latest product manuals www omegamanual info ZW REC zwSERIES WIRELESS RECEIVER TM Shop online at omega com User sGuide...

Страница 2: ...pecifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Страница 3: ...10 3 3 CONNECTING TO THE ZW REC 10 3 4 DEFAULT PASSWORDS 11 3 5 NAVIGATING THE WEBPAGE 11 4 END DEVICE READINGS AND CONFIGURATION 12 4 1 END DEVICE READINGS PAGE 12 4 2 CHANGING END DEVICE SETTINGS 1...

Страница 4: ...12 Figure 8 End Device Settings 13 Figure 9 End Device Status 15 Figure 10 Chart Page 16 Figure 11 Chart Toolbar 17 Figure 12 Chart Axis Dialog 17 Figure 13 System Information 18 Figure 14 Network Co...

Страница 5: ...rsist Failure to follow all instructions and warnings may result in injury 1 2 Environmental and Operating Conditions The ZW REC is designed to be fixed mounted and operated in a clean and dry environ...

Страница 6: ...shipping agent The carrier will not honor damage claims unless all shipping material is saved for inspection After examining and removing the contents save the packing material and carton in the event...

Страница 7: ...an also wirelessly update firmware for compatible End Devices and Sensors The ZW REC is designed to require no software to setup and run A standard web browser can be used to monitor and chart all sen...

Страница 8: ...Serial Number 3 USB Connector1 11 Network ID DIP Switches 4 Network Diagnostic LEDs 12 Network ID Label 5 Power Connector 13 MAC Address Label 6 Reset Button 14 IP Address Label 7 Ethernet Connector 1...

Страница 9: ...rt NIDs 0 to 7 UW Series End Devices require a 5 digit NID referred to as a PAN ID for configuration The PAN ID corresponding to each NID is listed in Table 1 Consult the user manual of each specific...

Страница 10: ...ning but this has no effect until the ZW REC is reset or power cycled Switch 3 is used to force DHCP on Changing Switch 3 to ON enables DHCP the next time the ZW REC is powered or reset Turning on DHC...

Страница 11: ...Align the back of the unit over the three clips When engaged slide downward and snap the unit in place When mounting the unit be sure to leave room on the top for the Antenna and on the bottom and si...

Страница 12: ...a default NID of 0 If this installation requires multiple Receivers ensure that each Receiver has a unique NID Record the NID on the Net Addr label on the back of the ZW REC for easy reference in the...

Страница 13: ...ding Page Figure 6 is shown by default when logging into the ZW REC The page will initially have no entries End Devices are automatically added to the page as they are connected to the ZW REC The End...

Страница 14: ...End Device Readings Page When logging into the ZW REC the End Device Readings page is displayed The readings page shows the current sensor data from all connected End Devices When an End Device turns...

Страница 15: ...refer to the Sensor User Manual for sensor specific instructions General Settings The End Device Name can be up to 16 characters long Names are displayed on the web pages with the Device ID to help di...

Страница 16: ...ntify mode The Clear End Device button removes the End Device from the ZW REC data base This will remove any Lost devices from the webpage and clear any errors If the Clear End Device button is presse...

Страница 17: ...te between pages of End Devices End Devices can be selected and filtered in the same way as the reading page Name Description Type Model of End Device Sensors Number of Sensors Connected Power Current...

Страница 18: ...n your needs Any combination of End Devices can be charted and two measurement types can be displayed at once Item Name Description 1 Toolbar Chart Utilities 2 Key Displayed Sensors 3 Axis 1 Axis for...

Страница 19: ...efault the cart will show one hour of data and scale each axis to fit the sensor readings received The scale on each axis can be fixed to user defined extents and the amount of time shown can also be...

Страница 20: ...or login is required for this page Changes to these settings could cause loss of connectivity to the webpages or the connected End Devices Care is advised when making any changes Some settings on this...

Страница 21: ...vided Host Name DHPS and DNS Server The default host name for the ZW REC is zwrec where are the last 4 digits of the MAC Address See Figure 2 for the location of the MAC address The ZW REC can be acce...

Страница 22: ...re to read data from the ZW REC using the ZW REC Serial Protocol detailed in the ZW REC Serial Programming Guide The default options work with the Omega Dashboard If different software is used these s...

Страница 23: ...e Save button to save any changes Changes in this section take place immediately Note It is highly recommended to uncheck the Enable Energy Scan Box after the first boot up This allows End Devices to...

Страница 24: ...to submit changes By default any password up to 16 characters long is allowed by the ZW REC If additional security is required check the require Strong Password box to enable the Strong Password Poli...

Страница 25: ...ficate that is not issued by a Certificate Authority CA Most web browsers provide a warning page when connecting to the ZW REC indicating the SSL certificate is not issues by a trusted certificate aut...

Страница 26: ...um Operating Temperature 0 to 70 C 32 to 158 F Humidity 90 RH non condensing Physical Properties Case Dimensions W x H x D 66 x 93 1 x 27 4mm Excluding Antenna Antenna Length 108mm Weight 90g Includin...

Страница 27: ...the directives listed below and carries the CE marking accordingly The following CE Mark is affixed to this equipment The CE declaration is available at the website listed on the cover page of this m...

Страница 28: ...that the website is authentic The ZW REC can automatically generate the required verification page The certificate issuer is allowed to remotely access to this page to verify the website To create a v...

Страница 29: ...ll reduce the risk of dropped packets or network traffic interfering with the upgrade B 1 Upgrading from Version 1 X ZW REC units running version 1 X firmware require a multi part update to run versio...

Страница 30: ...update is complete When the update has finished the Update Success screen in Figure 24 is shown Step 5 Connect to the ZW REC again using the IP Address recorded in Step 1 Follow the instruction in Se...

Страница 31: ...In firmware update mode encryption is disabled so the IP address needs to start with http Step 3 Press the Browse button and select the firmware b64 file for the update Press the Upgrade button to upd...

Страница 32: ...The Upload File button will now be usable Click the button to upload the firmware to the ZW REC The ZW REC will then update each selected End Device the next time it checks in The update process may...

Страница 33: ...nels in North America and Europe If the Wi Fi channels currently in use are known select an 802 15 4 channel that does not overlap with it to reduce interference C 2 Signal Strength Indicator Signal S...

Страница 34: ...When possible The ZW REC antenna should be parallel to the End Device antenna If the End Device does not have an external antenna the longest dimension of the End Device itself should be parallel to t...

Страница 35: ...uipment generates uses and radiates radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference However there is no guarantee that interfere...

Страница 36: ...aving a maximum gain of 2 2 dBi Antennas having a gain greater than 2 2 dBi are strictly prohibited for use with this device The required antenna impedance is 50 ohms D 2 CE Statement The following al...

Страница 37: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Страница 38: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Отзывы: