Design, Assembly and Service Manual
Page 41 of 44
Induction flow meter FMG600 series
EXIT
New password
Page through the menu using push-buttons (direction downwards) and (upwards). The selected menu
item appears on the first line with the first character blinking. Select “EXIT” and depress . The display will
read “Write to EEPROM Press any key“, usually . The meter programming mode will be terminated and
the data display menu will appear on the display. Use push-buttons and to page downwards and
upwards through the menu items.
Select “New password” to cancel the existing password and define a new password enabling entry into the
Parameter setting mode.
Menu:
Exit, depress / New password, depress
The display will read “Password 0000“. Using push-button move the cursor to the desired decimal position
and increase/decrease the selected figure by push-buttons and , respectively. Enter the new password
and depress . The display will read “Value entered Press any key”. Press any key, preferably . The Exit
menu will reappear on the display. Select the EXIT item and depress . The display will read “Write to
EEPROM Depress any key”. Press any key, preferably . This command will terminate the programming
mode and bring the data display menu on the meter display. Unless the programming procedure is
terminated in this way, the flow meter parameters will not be protected by a password. Page through the
menu items using push-buttons (direction downwards) and (upwards).