Design, Assembly and Service Manual
Page 1 of 44
Induction flow meter FMG600 series
Content
1. APPLICATION ............................................................................................................................................. 2
2. MEASUREMENT PRINCIPLE ..................................................................................................................... 2
3. TECHNICAL DESCRIPTION ....................................................................................................................... 3
3.1.
G
ENERAL
.................................................................................................................................................................. 3
3.2.
M
ETER DESIGN
........................................................................................................................................................... 3
3.2.1. Remote version ............................................................................................................................................... 3
3.2.2. Compact version .............................................................................................................................................. 4
4. TECHNICAL PARAMETERS ....................................................................................................................... 5
4.1.
F
LOW SENSOR
............................................................................................................................................................ 5
4.1.1. Selection of correct sensor size ....................................................................................................................... 5
4.1.2. Operational pressure of measured liquid .......................................................................................................... 6
4.1.3. Selection of electrode material ......................................................................................................................... 6
4.1.4. Sensor tube lining............................................................................................................................................. 6
4.1.5. Compact or remote meter version? .................................................................................................................. 6
4.1.6. Dimensions of flanged sensor .......................................................................................................................... 7
4.1.7. Dimensions Tri Clover sensor .......................................................................................................................... 8
4.1.8. Flow sensor specifications ............................................................................................................................... 9
4.2.
E
LECTRONIC UNIT BOX
................................................................................................................................................ 9
4.2.1. Electronic unit specifications .......................................................................................................................... 10
5. METER APPLICATION
RULES
..............................................................................................................................................
11
5.1.
S
ENSOR PLACEMENT IN PIPING
................................................................................................................................... 11
5.2.
S
ENSOR GROUNDING
................................................................................................................................................ 14
5.2.1. Flanged version .............................................................................................................................................. 14
5.2.2 Tri Clover ......................................................................................................................................................... 15
6. FLOW METER INSTALLATION AND OPERATIONAL START ............................................................... 16
6.1.
S
ENSOR INSTALLATION
.............................................................................................................................................. 16
6.2.
E
LECTRIC CONNECTIONS OF INDUCTION FLOW METER
................................................................................................... 17
6.2.1. Connection to power source .......................................................................................................................... 17
6.2.2. Output signal connections ............................................................................................................................. 18
6.3. CONNECTION BETWEEN SENSOR AND ELECTRONIC UNIT (REMOTE VERSION) ...................... 18
6.4.
C
ONNECTION BETWEEN SENSOR AND ELECTRONIC UNIT
(
REMOTE METER VERSION
,
PROTECTION CLASS
IP
68) .................. 19
6.5.
O
PERATIONAL START
................................................................................................................................................ 19
6.5.1 Operational start .............................................................................................................................................. 19
6.5.2. Operational data ............................................................................................................................................. 20
6.5.3.1. Display formats of aggregate values .......................................................................................................... 22
6.5.3.2. Data reset ................................................................................................................................................... 22
7. PROGRAMMING........................................................................................................................................ 23
7.1.
P
ROGRAMMING OF THE BASIC MENU ITEMS
.................................................................................................................. 24
7.1.1. Displayed data ............................................................................................................................................... 24
7.1.2. Samples ........................................................................................................................................................ 25
7.1.3. Analog output ................................................................................................................................................ 26
7.1.4. Output function .............................................................................................................................................. 29
7.1.5. Electrode cleaning .......................................................................................................................................... 34
7.1.6. Serial line ...................................................................................................................................................... 35
7.1.7. Production data ............................................................................................................................................. 37
7.1.8. Dose setting .................................................................................................................................................. 39
7.1.9. Zero setting ................................................................................................................................................... 40
7.1.10. 100 percent ................................................................................................................................................. 40
7.1.11. Exit .............................................................................................................................................................. 40
7.2.
T
HE
P
ARAMETER SETTING MENU
................................................................................................................................ 42
7.3.
T
HE
P
RODUCTION
D
ATA MENU
................................................................................................................................... 43
8. STANDARD TESTS ................................................................................................................................... 44
9. CALIBRATION AND VERIFICATION TESTS ........................................................................................... 44