Design, Assembly and Service Manual
Page 20 of 44
Induction flow meter FMG600 series
6.5.2. Operational data
The meter includes a two-line alpha-numeric display of 2 x 16 characters with
a background illumination. The display illumination function works in a power-saving mode where the
illumination is automatically switched off 120 seconds following the last push-button action. On depressing
any push-button, the display background illumination is reactivated.
The keyboard includes four push-button provided with the following symbols:
1. Push-button , the “roller” push-button, direction downwards
2. Push-button , movement upwards, in the direction of the arrow
3. Push-button , password entry push-button
4. Push-button , also referred to as the “enter” push-button
The meter display makes possible reading of up to nine different types of data. To switch to the desired type
of data, use pushbuttons (direction downwards) and (direction upwards).
To display temporary data, depress push-button
.
Depress push-button
again to return to the total data
display mode.
1. Flow rate
Average flow rate determined from the specified number of samples.
Display reading: Flow rate
2. Total
The total volume of the measured fluid passed through the meter sensor in the direction of the arrow on the
sensor body since the measurement start, or the temporary volume, i.e. the volume of fluid passed since the
last resetting of the temporary data.
Display reading: Total
3. Total volume -
The total volume of the measured fluid passed in the direction against the arrow on the sensor body since
the measurement started, or the temporary volume since the last resetting of the temporary volume – data.
Display reading: Total volume –
Flowrate
120.678 m3/h
Total
1234.567 m3
Temp.
765.432 m3
Total volume -
123.456 m3
Temp. volume -
65.321 m3