6.
Install the
nozzle body
Clean and Examine the Nozzle Assembly
Clean the nozzle assembly once a week, or more frequently if needed, to keep the orifice assembly free of mineral
buildup that degrades cutting performance. A clean orifice assembly also helps to prolong the life of the mixing tube.
NOTICE
Handle the nozzle carefully to prevent damage to the abrasive tubing retention tube.
1.
Remove the
mixing tube
.
2.
Remove the nozzle body.
Remove the Nozzle Body from an A-Jet
.
• For the Motorized Z-Axis, go to
Remove the Nozzle Body from a Motorized Z-Axis
.
Remove the Nozzle Body from a Tilt-A-Jet
3.
Fill an ultrasonic cleaner with white vinegar.
4.
Remove the
mixing tube collet
[1],
collet O-ring
[2], and
mixing tube nut
[3].
Figure 51
5.
Remove the
O-rings
from the
nozzle body
.
Figure 1
6.
Put the
nozzle body
,
mixing tube
,
mixing tube nut
, and
collet
in the ultrasonic cleaner for 3—5 minutes or
until the
jewel orifice
is clean.