25
400715D-EN
3.
Make sure the
mixing tube
remains flush and sits firmly against the
mixing chamber
[1], then tighten the
mixing tube nut
by hand.
Figure 39
NOTICE
Do not over or under tighten the mixing tube nut. Over tightening the mixing tube nut can cause the mixing
tube and the orifice to become misaligned and cause damage. Under tightening the mixing tube nut can
cause the mixing tube to come out of the nozzle when high-pressure water is activated.
4.
Hold the
nozzle body
to counteract the torque and torque the
mixing tube nut
.
Figure 40
Clean or Replace the Final Filter
There are two types of filter assemblies available for the MAXJET 5i nozzle. The
metal filter screen that is cleaned and used again. The
has a plastic filter and is replaced when
clogged.
NOTICE
If there is a leak between the inlet body and the nozzle body, make sure that the inlet body, nozzle, and
filter components are clean and free from dirt and abrasive. On the A-Jet, clean the components, then
replace the ring seal and O-ring. See
Clean the Metal Screen Filter Assembly
. Over tightening the nozzle
body damages the sealing surface.
n
To clean the metal filter screen, go to
Clean the Metal Screen Filter Assembly
n
Содержание MAXJET 5i 305617 Series