WARNING
●
Do not insert the insertion tube into an inspection object that is in operation or
conducting electricity.
Otherwise, the insertion tube may be damaged by being caught inside of the inspection
object, etc., or the insertion tube may touch the object, which results in electric shock.
●
Before storing the instrument in its carrying case, be sure to turn OFF the power and
remove the battery.
Leaving the battery loaded during storage causes it to be hot, which may cause fire.
●
The gas tube must not be used for grounding.
Otherwise, it may cause an explosion.
CAUTION
●
Do not use the instrument in any environment (including strongly radioactive
environments) other than the specified operating environment.
Otherwise, unexpected accidents that may damage the insertion tube may result.
●
Note the following precautions when moving this unit to or using it at an elevated
location.
–
Conduct a prior inspection
–
Take measures to prevent the unit from falling off
–
Implement thorough safety measures
●
Pay careful attention to the temperature of the distal end and the insertion tube right
after using this instrument in high temperature environments as the temperature does
not cool down immediately.
Otherwise, you may get burned.
●
Do not grip the control for a prolonged period of time when using the unit under a high
temperature.
Otherwise, it may cause low-temperature burns. Take precautionary measures such as
wearing protective gloves to prevent low-temperature burns.
●
Pay attention not to trip over the power cord or cables of the insertion tube.
●
Do not use commercially-sold electronic transformers for overseas travel use (travel
converters).
●
Use only the power cord and the AC adapter specified by Olympus and connect the
power cord to the power outlet within the rated range.
Otherwise, smoke, fire, or electric shock may occur.
●
Do not use the power cord specified for this instrument for other products.
●
Do not use the AC adapter outdoors.
Otherwise, electric shock, smoke or fire may occur, which may cause damage to the
instrument.
The AC adapter is designed for indoor use.
●
Do not apply a strong impact to the AC adapter by hitting it against the wall or dropping
it to the floor, etc.
Otherwise, the malfunction or damage may be caused and result in electric shock.