Page 13
921468007_90_005
6.3 Entrance, exit, extra time settings
The exit time must be sufficient enough for the user to leave the guarded area
before the system arms. Entry time should be enough for the user to enter the
password for system disarm. It is advisable not to be marginal, in case of accidentally
mistyped passwords. If a password is typed from a wireless keypad, an extra 5
seconds should be taken care of, in order to open and unlock the keypad. It is
suggested that the input time is not less than 30 seconds when a wireless keyboard
is used. As far as the extra time is concerned, it may be necessary for some zone to
take extra time from the normal delay. For example, if some user needs to arm the
system, but also needs to leave with the car from the garage, he could set the garage
door zone as a "NEXT DELAY" zone and set its extra time by "TECHNICIAN MENU"
"SETTINGS"
"EXTRA EXIT TIME". This additional time is also added when entering
in an armed system. This extra time is rarely used. It is suggested that "NEXT DELAY"
zones to be placed in a separate section. So some user could have one section with
motion sensors, one with magnetic sensors set to "NEXT DELAY" and one with the
other magnetic sensors.
6.4 Zones bypass
–
forced arm
It is suggested that motion sensors have the following options during setup: Bypass
= "NO", Forced Arm = "YES". In that way the user can arm the system, bypassing
them, but as soon as he leaves, the devices are able to give an alarm event. As far as
magnetic contacts are concerned, they are usually chosen not to be bypassed, in
order to prevent the system from arming and notify the user to secure those zones
(close an open window). The setting for this is Bypass = "NO" and Forced Arm =
"NO". The keypad notifies the user one-by-one for zones that do not let the system
arm. When all doors and windows are closed, the system starts the exit countdown
without having to re-enter the password. If a user wants to be able to leave a
window open when the system is armed, then the "FORCED ARM" option for this
zone should be selected "YES".