background image

Page 14 

921468007_90_005 

 

7. HANDLING THE SYSTEM WITH THE WIRELESS KEYPAD 

 

7.1 Key Operations and Functions of the Wireless Keyboard 

 

 

 

 

 

 

 

Содержание BS-429/W

Страница 1: ...WIRELESS BURGLAR ALARM SYSTEM BS 468 A QUICK INSTALLATION GUIDE ...

Страница 2: ...SS DEVICES 9 4 STARTING UP THE INSTALLED SYSTEM 10 4 1 SYSTEM CONFIGURATION 10 4 2 INSTALLATION COMPLETION 11 5 DEVICES INSTALLATION 11 5 1 Generals 11 5 2 Device s control operation 12 6 BASIC SYSTEM CONFIGURATION 12 6 1 Zone settings 12 6 2 Section configuration 12 6 3 Entrance exit extra time settings 13 6 4 Zones bypass forced arm 13 7 HANDLING THE SYSTEM WITH THE WIRELESS KEYPAD 14 7 1 Key Op...

Страница 3: ... 20 8 1 General 20 8 2 Installation 21 8 3 Codes registration procedure on rf 467 21 8 4 CODES DELETION PROCEDURE ON RF 467 22 9 System s app 22 9 1 Program for PC PC 468 A 22 9 2 Mobile app i olympia Android iOS 22 10 Alarm s faults 23 11 Warranty 24 ...

Страница 4: ...tion in addition to this manual please refer to the BS 468 A manual which is also enclosed within the kit as well as the instructions for the individual devices that are enclosed in the packaging of each device You should keep in mind that during the installation procedure the wireless keyboard should not be left unnecessarily active in the technician menu For every half hour that its screen is ac...

Страница 5: ...larm panel 1 PC BS 479 32 wireless zone expansion module for BS 468 A 1 PC RF 467 Remote control transmitter 433MHz for BS 468 BS 468 A panel 2 PCS YET205B 630 MODULE RECEIVER 433MHz RECEIVER MODULE 4 CODES 1 OUTPUT PER CODE 1 PC A 986 12V 12V 7Ah sealed lead acid battery 1 PC 1 3 Starting the installation Make sure the BS 479 extension is mounted on the panel All the wireless peripheral devices t...

Страница 6: ...please refer to the user manual Section 3 6 Programming via computer B BS 466 A wired Keyboard The installation process through the wired keyboard is the same as that of the wireless keyboard in steps 3 and 5 see installation mode C C BS 479 wireless extension and BS 477 Wireless Keyboard NOTE For basic and specialized keyboard operations and panel s settings please refer to Section 4 of this guid...

Страница 7: ...includes the devices detection and the second installs a wireless keypad When the BS 477 wireless keypad is installed the installation of the other devices can be completed by the keypad menu In order to continue focus on the BT1 button and the LD4 LED green of the BS 479 card The total time of the STEP 1 procedure is about 2 minutes First the BS 468 A panel should recognize the BS 479 wireless zo...

Страница 8: ... carried out by the menu NETWORK INSTALLATION 1 Press Go to MASTER OR TECH MENU By entering the technician code the user has now TECHNICIAN privileges 2 Go to WIRELESS NETWORK Press Choose NETWORK INSTALLATION and the wireless devices detection starts At the bottom left corner of the screen there is a counter counting the seconds After 999 seconds if no device is added the installation process sto...

Страница 9: ...ed every few seconds When refresh occurs 4 flashing dots appear on screen Prices above 30 means good signal 19 to 30 average signal and below 19 means low signal Beyond this value communication is possible but there will be a large number of lost packets It is not recommended to install a device when the mark is below 20 If at some point there is insufficient signal for a device think of a better ...

Страница 10: ...WIRELESS TAMPERS This feature allows the user to monitor in real time whether the tamper spring of each wireless device installed on the network is pressed or not The numbers displayed are the wireless zones tamper states Press and release the tamper springs one by one and observe the corresponding zone indicator turning off for a few seconds while spring is pressed down or on spring is released W...

Страница 11: ...tall them on the system The installation procedure has come to its end You have set up an operating system and you know all the basic details to operate this system You can try an arm disarm test to check that this function is running properly CAUTION For optimal system operation when entering a password either to enter or exit the guarded area do not type something on the keypad or open close doo...

Страница 12: ...ED on the radar lights up and the keypad screen changes Let it be noted that radars turn on the LED on each activation only in the technician menu Be careful if a zone is in Disabled Off mode The sensor activation alert never flashes even if it exists 6 BASIC SYSTEM CONFIGURATION 6 1 Zone settings The entry exit points of the guarded space must be set as Zone with delay for the user to have enough...

Страница 13: ...o added when entering in an armed system This extra time is rarely used It is suggested that NEXT DELAY zones to be placed in a separate section So some user could have one section with motion sensors one with magnetic sensors set to NEXT DELAY and one with the other magnetic sensors 6 4 Zones bypass forced arm It is suggested that motion sensors have the following options during setup Bypass NO F...

Страница 14: ...Page 14 921468007_90_005 7 HANDLING THE SYSTEM WITH THE WIRELESS KEYPAD 7 1 Key Operations and Functions of the Wireless Keyboard ...

Страница 15: ...DEVICE ASSIGN ZONE NETWORK INSTALLATION DELETE SINGLE ZONE DELETE ALL ZONES RF COMM SUPERVISION WIRELESS TAMPERS WIRELESS SENSORS SIGNAL STRENGTH SIREN LED SETTING RF MASTER INFO 7 2 Basic Menu Password Password 9 9 9 9 1 2 3 4 ______MEΝU______ BYPASS ZONES BYPASS W LESS ZONES MASTER OR TECH MENU WIRED ZONE CONDITION WLESS ZONE CONDITION LAST ALARMS ALL EVENTS MANUAL OUTPUTS CHECK INFORMATION Appe...

Страница 16: ...is locked Therefore once the device is switched on it is not necessary for the user to press first but can press for 5 seconds and send a panic alarm 7 4 Basic handling and settings The panel has 1 main code master code which by default is set to 1 2 3 4 and up to 50 user codes which by default are not programmed The system can operate in two different modes Depending on the mode of operation the ...

Страница 17: ...to disarm each subsystem The arming of one subsystem does not affect the status armed disarmed of the other subsystems If during the arming procedure a zone is active then the keyboard shows the message Which means that on zone 5 Kitchen a window has been left open If we press the arm command is canceled If we press or close the kitchen window we see This message is shown for 1 second and immediat...

Страница 18: ...his means that it is disabled but would prevent the panel from arming if it was not disabled Selecting BYPASS W LESS ZONES we see The same applies for wireless zones The only difference is that the zone numbers are 25 56 wireless zones Selecting WIRED ZONE CONDITION In the following window we can test the good operation of the zones and the devices connected to them For examples if a magnetic cont...

Страница 19: ...s the 70th event of a total of 70 events With the up and down arrow keys 2 and 8 the user can see all the registered events The event memory has a capacity of 250 events and once filled the new event will erase the oldest The events that are registered are errors alarms user and technician menu accesses as well as the arming and disarming of the system The main user and the technician can both era...

Страница 20: ... alarm event only if the system is armed While the system is disarmed an information on the WIRELESS SENSORS menu screen is depicted If a wireless device does not communicate with the panel for a long time 2 hours in a disarmed system it is recorded as an error in the events log If the same error occurs in an armed system an alarm will be triggered If the battery level on a wireless device is low ...

Страница 21: ...ctions A System arming B System disarming C Silent alarm D Panic alarm Photo 1 RF 467 Photo 2 BS 468 A panel Top View Photo 3 YET 250B 630 wireless receiver YET 205B 630 Photo 3 is a wireless receiver for BS 468 A It uses scroll codes and has the ability to learn codes from the RF 467 remote control transmitter It can store codes from up to 6 transmitters 8 2 Installation Installation or maintenan...

Страница 22: ...dure on rf 467 Press the YET 205B 630 BT key continuously and note that the LED E remains on Do not stop pressing the key and after about 5 seconds the blue LED E goes out indicating that the codes are now erased Note The deletion process deletes all registered remote controls 9 SYSTEM S APP 9 1 Program for PC PC 468 A You can download the application visiting the site of Olympia Electronics www o...

Страница 23: ...card installed and it has now been removed or is not working Check the card s connection with the panel If the error does not disappear in a few minutes contact your technician EXTENSION NO CONNECTED UNIT A new extension has been connected and is not registered Select the SYSTEM SCAN EXTENSIONS menu from the technician menu ZONE xx DEVICE COMM TIMEOUT An installed wireless device on zone xx is no ...

Страница 24: ...ided or has any repairs or re setting done by a third party unless Olympia Electronics has fully agreed to them in writing Products that have been damaged can be returned to the premises of our company for repair or replacement as long as the warranty period is valid Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the re...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Отзывы: