2H0/2HZ
1-3-42
U101
Setting the other high voltages
Description
Sets the developing bias control voltage, the transfer control voltage and the separation control voltage or
checks the output of these voltages. Sets the transfer control voltage and the separation control voltage ON/
OFF timing.
Purpose
To check the developing bias, the transfer voltage and the separation voltage or to take measures against
drop of image density or background fog.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the setting using the +/- keys.
Increasing the DEV BIAS setting makes the image darker; decreasing it makes the image lighter.
Increasing the DEV SBIAS setting makes the image darker.
Increasing the DEV DUTY setting makes the image lighter; decreasing it makes the image darker.
Increasing the TC DATA/TC DATA2 setting makes the transfer voltage higher, and decreasing it makes
the voltage lower.
Increasing the SC DATA setting makes the separation voltage higher, and decreasing it makes the volt-
age lower.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U110
Checking the drum count
Description
Displays the drum counts for checking.
Purpose
To check the drum status.
Method
Press the start key. The drum counter count is displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
Setting
range
Initial
setting
DEV BIAS
Developing bias AC component frequency at image
formation
20 to 32
26
DEV SBIAS
Developing shift bias potential at image formation
0 to 255
58
DEV DUTY
Developing bias AC component duty at image forma-
tion
0 to 100
50
TC DATA
Transfer control voltage
0 to 255
89
SC DATA
Separation control voltage
0 to 2
1
TC DATA2
Transfer control voltage for small sizes
0 to 255
115
TC ON
Time of period since the registration clutch is turned
on until the transfer voltage is turned on
0 to 255
91
TC OFF
Time of period since the registration clutch is turned
off until the transfer voltage is turned off
0 to 255
68
SC ON
Time of period since the registration clutch is turned
on until the separation voltage is turned on
0 to 255
40
SC OFF
Time of period since the registration clutch is turned
off until the separation voltage is turned off
0 to 255
92
Service Manual
Y108620-5
Содержание d-Copia 2500MF
Страница 1: ...d Copia 2500MF d Copia 3000MF Digital Copier SERVICE MANUAL Code Y108620 5...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 14: ...2H0 2HZ This page is intentionally left blank...
Страница 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank Service Manual Y108620 5...
Страница 258: ...2H0 2HZ 2 1 20 This page is intentionally left blank Service Manual Y108620 5...
Страница 296: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2007 1ST EDITION 296 Y108620 5...