2H0/2HZ
1-5-52
(9) Adjusting front position of the fuser unit (adjusting lateral squareness)
Follow the procedure below if the drum is not parallel to the fuser unit and therefore paper is not fed straight to the fuser
section and the trailing edge of image on either the front or rear side becomes longer.
Procedure
Figure 1-5-94
Figure 1-5-95
Tighten the two screws. Refit the front
left cover and close the front cover.
Open the front cover and remove the
front left cover (see page 1-5-40).
Loosen the screw holding each of the
fuser unit and adjusting spacer.
For copy example 1:
Move the adjusting spacer in the direction
of the white arrow ( ) to raise the front
position of the fuser unit.
For copy example 2:
Move the adjusting spacer in the direction
of the black arrow ( ) to lower the front
position of the fuser unit.
Yes
No
Press the start key and make
a test copy at 100 % magnification.
Start
End
Is the image correct?
Place the original on the platen.
Original
Copy
example 1
Copy
example 2
Adjusting spacer
Screw
Fuser unit
Service Manual
Y108620-5
Содержание d-Copia 2500MF
Страница 1: ...d Copia 2500MF d Copia 3000MF Digital Copier SERVICE MANUAL Code Y108620 5...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 14: ...2H0 2HZ This page is intentionally left blank...
Страница 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank Service Manual Y108620 5...
Страница 258: ...2H0 2HZ 2 1 20 This page is intentionally left blank Service Manual Y108620 5...
Страница 296: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2007 1ST EDITION 296 Y108620 5...