2H0/2HZ
1-3-21
U034
Adjustment: Center line adjustment
1. Select the item to be adjusted.
*: Setting the difference value from reference value
2. Press the system menu key.
3. Press the start key to output a test pattern.
4. Press the system menu key.
5. Change the setting value using the +/- or numeric keys.
For output example 1, decrease the value. For output example 2, increase the value.
Figure 1-3-5
6. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
Maintenance
item No.
Description
Display
Description
Setting
range
Initial
setting
Change in
value per step
LEFT
Adjustment of reference value
0 to 1000
180
0.042 mm
MP TRAY
Paper feed from MP tray*
-500 to 500
0
0.042 mm
CASSETTE 1
Paper feed from cassette 1*
-500 to 500
0
0.042 mm
CASSETTE 2
Paper feed from cassette 2*
-500 to 500
0
0.042 mm
CASSETTE 3
Paper feed from optional cassette 3*
-500 to 500
0
0.042 mm
CASSETTE 4
Paper feed from optional cassette 4*
-500 to 500
0
0.042 mm
DUPLEX
Duplex mode (second side)*
-500 to 500
0
0.042 mm
Center line of printing
Correct image
Output
example 1
Output
example 2
U034
U067
U072
Y108620-5 Service Manual
Содержание d-Copia 2500MF
Страница 1: ...d Copia 2500MF d Copia 3000MF Digital Copier SERVICE MANUAL Code Y108620 5...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 14: ...2H0 2HZ This page is intentionally left blank...
Страница 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank Service Manual Y108620 5...
Страница 258: ...2H0 2HZ 2 1 20 This page is intentionally left blank Service Manual Y108620 5...
Страница 296: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2007 1ST EDITION 296 Y108620 5...